2MF/2MG-5
1-3-14
U034
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
Adjustment: [LSU Out Left]
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
5. Change the setting value using the cursor left/rigrt keys or numeric keys.
For output example 1, increase the value. For output example 2, decrease the value.
Figure 1-3-3
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
U034
U066
(P.1-3-17)
U071
(P.1-3-21)
Display
Description
Setting
range
Initial
setting
Change in
value per step
MPT
Standard value adjustment
0 to 1180
305
1dot
MPT
Paper feed from MP tray
-70 to 70
22
1dot
Cassette1
Paper feed from optional cassette1 -70 to 70
0
1dot
Cassette2
Paper feed from optional cassette2 -70 to 70
0
1dot
Cassette3
Paper feed from optional cassette3 -70 to 70
0
1dot
Cassette4
Paper feed from optional cassette4 -70 to 70
0
1dot
Duplex
Duplex mode (second)
-70 to 70
0
1dot
Center line of printing
(within ± 2.0 mm)
Correct image
Output
example 1
Output
example 2
U034
U067
(P.1-3-18)
U072
(P.1-3-23)
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...