2MF/2MG
1-3-35
U425
Setting the target
Description
Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for
adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
3. Select the item to be set using the cursor up/down keys.
4. Enters the value that is indicated on the back of the chart using the cursor left/right keys or
numeric keys.
5. Press the start key. The value is set.
Item No.
Description
Display
Description
N875
Setting the N875 patch for the original for adjustment
N475
Setting the N475 patch for the original for adjustment
N125
Setting the N125 patch for the original for adjustment
CYAN
Setting the cyan patch for the original for adjustment
MAGENTA
Setting the magenta patch for the original for adjustment
YELLOW
Setting the yellow patch for the original for adjustment
RED
Setting the red patch for the original for adjustment
GREEN
Setting the green patch for the original for adjustment
BLUE
Setting the blue patch for the original for adjustment
ADJUST ORIGINAL
Setting the main and auxiliary scanning directions
Display
Description
Setting range
L
Setting the L value
0.0 to 100.0
a
Setting the a value
-200.0 to 200.0
b
Setting the b value
-200.0 to 200.0
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...