2MF/2MG
1-3-50
U633
Setting the V.34 symbol speed (3429 Hz)
Sets if the V.34 symbol speed 3429 Hz is used.
1. Select the setting using the cursor up/down keys.
* : Initial setting: ON
2. Press the start key. The setting is set.
Setting the number of times of DIS signal reception
Sets the number of times to receive the DIS signal to once or twice. Used as one of the correction
measures for transmission errors and other problems.
1. Select the setting using the cursor up/down keys.
* : Initial setting: ONCE
2. Press the start key. The setting is set.
Setting the reference for RTN signal output
Sets the error line rate as the reference for RTN signal output. If transmission errors occur fre-
quently due to the quality of the line, they can be reduced by lowering this setting.
1. Select the setting using the cursor up/down keys.
* : Initial setting: 15%
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
Display
Description
ON
V.34 symbol speed 3429 Hz is used.
OFF
V.34 symbol speed 3429 Hz is not used.
Display
Description
ONCE
Responds to the first signal.
TWICE
Responds to the second signal.
Display
Description
5%
Error line rate of 5%
10%
Error line rate of 10%
15%
Error line rate of 15%
20%
Error line rate of 20%
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...