2MF/2MG
1-3-52
U641
Setting communication time 2
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Setting the T0 time-out time
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the
destination unit, a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the cursor left/right keys.
2. Press the start key. The value is set.
Setting the T1 time-out time
Sets the time before receiving the correct signal after call reception. No change is necessary for
this maintenance item.
1. Change the setting using the cursor left/right keys.
2. Press the start key. The value is set.
Item No.
Description
Display
Description
T0 TIME OUT
Sets the T0 time-out time.
T1 TIME OUT
Sets the T1 time-out time.
T2 TIME OUT
Sets the T2 time-out time.
Ta TIME OUT
Sets the Ta time-out time.
Tb1 TIME OUT
Sets the Tb1 time-out time.
Tb2 TIME OUT
Sets the Tb2 time-out time.
Tc TIME OUT
Sets the Tc time-out time.
Td TIME OUT
Sets the Td time-out time.
Description
Setting range
Initial setting
T0 time-out time
30 to 90 s
56
Description
Setting range
Initial setting
T1 time-out time
30 to 90 s
36
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...