Troubleshooting
Service errors
FS-6700
E4 - Fuser heater error
Table 6. 12 E4 error
Meaning
Suggested causes
Corrective action
The fuser heater is not intact
due to disconnection or the
circuit failure.
• Blown-out thermistor
• Improper connector inser-
tion
• Blown-out halogen heater
• Blown-out thermostat
• Comparator defect on the
engine board
• Defective engine CPU
(input port)
• Defective gate array
(input/output port opera-
tion)
Follow the flow chart on the
next page.