2M2/2M3
1-5-11
(2) Detaching and refitting the operation panel PWB
Procedure
1. Remove the control unit (see page 1-5-
7).
2. Unhook the two hooks and then remove
the operation panel unit.
Figure 1-5-17
3. Unhook the two hooks and then remove
the operation panel PWB.
4. Check or replace the operation panel
PWB and refit all the removed parts.
Figure 1-5-18
Hook
Hook
Operation panel unit
Operation panel unit
Operation panel PWB
Hooks