background image

INSTALLATION MANUAL

FOR THE

OF

SOLAR PHOTOVOLTAIC POWER MODULES

Please read this manual carefully before installing the modules.

KYOCERA CORPORATION

1. INTRODUCTION

As the world leader in development and application of high technology ceramic/silica materials, Kyocera Corporation
(KC) offers a wide range of highly efficient and reliable crystalline silicon solar photovoltaic (PV) power modules.
Kyocera began to extensively research PV technology in 1975 and commenced manufacturing operations in 1978.
Since then, Kyocera has supplied millions of cells and modules throughout the world. With years of experience and
state-of-the-art technology, Kyocera provides the highest quality PV power modules in a range of sizes designed to
meet the requirements of the most demanding energy  and power users worldwide.

2. POWER MODULES

Kyocera power modules consist of a series of electrically interconnected crystalline silicon solar cells. Which are
permanently laminated within an ethylene-vinyl-acetate (EVA) pottant and encapsulated between a tempered glass
cover plate and a poly-vinyl-flouride (PVF) back sheet. The entire laminate is secured within an anodized aluminum
frame for structural strength, ease of installation, and to protect the cells from the most severe environmental
conditions.

3. APPLICATIONS

Kyocera modules are a reliable, virtually maintenance-free direct current (DC) power source, designed to operate most
efficiently in sunlight. Kyocera modules are ideal to power remote homes, recreational vehicles, water pumps,
telecommunication systems and many other applications either with or without the use of storage batteries.

4. WARNINGS

Solar modules generate electricity when exposed to light. Arrays of many modules can cause lethal shock and burn
hazards.  Only authorized and trained personnel should have access to these modules.  To reduce the risk of electrical
shock or burns, modules may be covered with an opaque material during installation to avoid shocks or burns. Do not
touch live terminals with bare hands. Use insulated tools for electrical connections.

PERMIT

 Before installing your solar system, contact local authorities to determine the necessary permit, installation and

inspection requirements.

INSTALLATION AND OPERATION

 Systems should be installed by qualified personnel only. The system involves electricity, and can be dangerous if

the personnel are not familiar with the appropriate safety procedures.

  Do not step on the module.

 Although KYOCERA modules are quite rugged, the glass can be broken (and the module will no longer work

properly) if it is dropped or hit by tools or other objects.

  Sunlight shall not be concentrated on the module.

 

The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is subject to a
salt water environment with contact to a rack of another type of metal.(Electrolysis Corrosion) If required, 

PVC or

stainless steel washers can be placed between the solar module frame and support structure to prevent this type of

KC-SERIES

Summary of Contents for KC-120-1

Page 1: ...erate most efficiently in sunlight Kyocera modules are ideal to power remote homes recreational vehicles water pumps telecommunication systems and many other applications either with or without the use of storage batteries 4 WARNINGS Solar modules generate electricity when exposed to light Arrays of many modules can cause lethal shock and burn hazards Only authorized and trained personnel should h...

Page 2: ...ulated and ventilated battery case specifically designed for the purpose 5 SITE SELECTION In most applications KC modules should be installed in a location where they will receive maximum sunlight throughout the year In the Northern Hemisphere the modules should typically face south and in the Southern Hemisphere the modules should typically face north Modules facing 30 degrees away from true Sout...

Page 3: ...means are employed this may affect the Listing For Fire Class Ratings RACK The supporting frame is used to mount modules at correct tilt angles The modules are not designed for integral mounting as part of a roof or wall The mounting design may have an impact on the fire resistance FOOT ANGLE SUPPORT LEGS MOUNTING HOLE ARRAY FRAME MODULE Figure 2 Basic Rack or Standoff Mounting Structure 8 MODULE ...

Page 4: ...fuse is 4 12 amperes Figure 5 Interconnect Cable Clamp H After checking that module wiring is correct close and secure all the junction boxes Use a Phillips head screw driver to secure all screws on the junction box cover to ensure a waterproof seal 9 GROUNDING We recommend you attach all module frames to an earth ground Attach a separate ground wire to one of the holes marked ground on the module...

Page 5: ... connections will result in a damaged module or array 13 SPECIFICATIONS The electrical and physical specifications can be found at the end of this document Table 2 NOTES The electrical characteristics are within 10 percent of indicated values of Isc Voc and Pmax under standard test conditions irradiance of 1KW m2 AM 1 5 spectrum and cell temperature of 25 Under certain conditions a photovoltaic mo...

Page 6: ...ectrical specifications are under test conditions of irradiance of 1kW M2 Spectrum of 1 5 air mass and cell temperature of 25o C Physical Characteristics Model Number KC 120 1 KC 80 KC 70 KC 60 KC 50 KC 45 KC 40 KC 35 Length Inches mm 56 1 1425 38 4 976 34 1 865 29 6 751 25 2 639 22 6 573 20 7 526 18 5 471 Width Inches mm 25 7 652 25 7 652 25 7 652 25 7 652 25 7 652 25 7 652 25 7 652 25 7 652 Dept...

Page 7: ...MODULE MOUNTING DIMENSIONS MODULE MOUNTING SPECIFICATIONS DO NOT USE DO NOT USE KYOCERA KC SERIES ...

Reviews: