Table 2. Kyocera KC-Family Module Specifications
Electrical Characteristics:
Model Number
KC-120-1
KC-80
KC-70
KC-60
KC-50
KC-45
KC-40
KC-35
Rated Power, Watts (Pmax)
120
80
70
60
50
45
40
35
Open circuit Voltage (Voc)
21.5
21.5
21.5
21.5
21.5
19.2
21.5
18.8
Short Circuit Current (Isc)
7.45
4.97
4.35
3.73
3.1
3.1
2.48
2.5
Voltage at Load (Vmp)
16.9
16.9
16.9
16.9
16.7
15
16.9
15
Current at Load (Imp)
7.1
4.73
4.14
3.55
3
3
2.34
2.33
Maximum System Voc
600
600
600
600
600
600
600
N/A
Factory Installed Bypass Diode (Qty)
yes (6)
yes (6)
yes (6)
yes (4)
yes (4)
yes (4)
yes (4)
yes (4)
Series Fuse Rating (Amps)
11
7
7
6
6
6
6
6
NOTE
: The Electrical specifications are under test conditions of irradiance of 1kW/M
2
, Spectrum
of 1.5 air mass and cell temperature of 25
o
C
Physical Characteristics:
Model Number
KC-120-1
KC-80
KC-70
KC-60
KC-50
KC-45
KC-40
KC-35
Length, Inches (mm)
56.1
(1425)
38.4
(976)
34.1
(865)
29.6
(751)
25.2
(639)
22.6
(573)
20.7
(526)
18.5
(471)
Width, Inches (mm)
25.7 (652)
25.7
(652)
25.7
(652)
25.7
(652)
25.7
(652)
25.7
(652)
25.7
(652)
25.7
(652)
Depth (frame, Inches (mm)
1.42 (36) 1.42 (36) 1.42 (36) 1.42 (36) 1.42 (36) 1.42 (36) 1.42 (36) 1.42 (36)
Depth (including j-box), inches (mm)
2.0 (52)
2.0 (52)
2.2 (56)
2.0 (52)
2.1 (54)
2.1 (54)
2.0 (52)
2.1 (54)
Weight, Pounds (kg)
23.6 (11.9) 21.2 (9.6) 15.4 (7.0) 13.2 (6.0) 11.0 (5.0) 9.9 (4.5) 9.9 (4.5) 8.8 (4.0)
Mounting Hole Diameter, inches (mm) *
0.28" (7)
0.28" (7) 0.28" (7) 0.28" (7) 0.28" (7) 0.28" (7) 0.28" (7) 0.28" (7)
*Note
: See Module Mounting Specifications for Hole Location on Frame