Standard Test Conditions
KD205GX-LPU
KD210GX-LPU
KD215GX-LPU
P
max
205
210
215
W
V
mp
26.6
26.6
26.6
V
I
mp
7.71
7.90
8.09
A
V
oc
33.2
33.2
33.2
V
I
sc
8.36
8.58
8.78
A
P
tolerance*
+5/-0
+5/-0
+5/-0
%
electrIcal
SPECIFICATIONS
Nominal Operating Cell
Temperature Conditions (NOCT)
t
NOct
47.9
47.9
47.9
O
C
P
max
145
149
152
W
V
mp
23.6
23.6
23.6
V
I
mp
6.17
6.32
6.47
A
V
oc
30.0
30.0
30.0
V
I
sc
6.78
6.62
7.12
A
KYOcera SOlar, INc.
800-223-9580 toll-free 800-523-2329 fax www.kyocerasolar.com
102010
MecHaNIcal
SPECIFICATIONS
MOUNtINg HOLEs
gROUNDINg HOLEs
DRAINAgE HOLEs
legend
1.8in
46mm
LABEL
CABLE w/
CONNECtOR
JUNCtION
BOx
4.25in
108mm
4.13in
105mm
37.4in/950mm
29.5in/750mm
37.99(±0.1)in
965±2.5mm
Weight: 39.7lbs (18.0kg)
10.96in
278.5mm
18.56in
471.5mm
59.06in
1500mm
AUTHORIzED DISTRIbUTOR
10.96in
278.5mm
18.56in
471.5mm
KD200-54 P Series
Temperature Coefficients
P
max
-0.938
-0.964
-0.991
W/
o
C
V
oc
-0.120
-0.120
-0.120
V/
o
C
I
sc
0.00502
0.00515
0.00527
A/
o
C
Operating
temp
-40~90
-40~90
-40~90
O
C
System Design
Series Fuse Rating
15 A
Maximum DC System Voltage (UL)
600 V
Kyocera reserves the right to modify these specifications without notice.
All specification at 25°C. cell temperature, 1.5 AM and 1000W/m
2
.
NEC 2008 Compliant
UL 1703 Listed
KYOcera SOlar, INc.