Standard Test Conditions
KD230GX-LPB
KD235GX-LPB
P
max
230
235
W
V
mp
29.8
29.8
V
I
mp
7.72
7.89
A
V
oc
36.9
36.9
V
I
sc
8.36
8.55
A
P
tolerance*
+5/-3
+5/-3
%
electrIcal
SPECIFICATIONS
Nominal Operating Cell
Temperature Conditions (NOCT)
t
NOct
47.9
47.9
O
C
P
max
163
166
W
V
mp
26.4
26.4
V
I
mp
6.18
6.31
A
V
oc
33.3
33.3
V
I
sc
6.78
6.93
A
Temperature Coefficients
P
max
-1.04
-1.07
W/
o
C
V
oc
-0.133
-0.133
V/
o
C
I
sc
0.00502
0.00513
A/
o
C
Operating
temp
-40~90
-40~90
O
C
System Design
Series Fuse Rating
15 A
Maximum DC System Voltage (UL)
600 V
Kyocera reserves the right to modify these specifications without notice.
All specification at 25°C. cell temperature, 1.5 AM and 1000W/m
2
.
NEC 2008 Compliant
UL 1703 Listed
KYOcera SOlar, INc.
800-223-9580 toll-free 800-523-2329 fax www.kyocerasolar.com
122210
MecHaNIcal
SPECIFICATIONS
MOUNtINg HOLEs
gROUNDINg HOLEs
DRAINAgE HOLEs
legend
1.8in
46mm
CABLE w/
CONNECtOR
JUNCtION
BOx
4.25in
108mm
4.13in
105mm
40.55in/1030mm
32.68in/830mm
37.99(±0.1)in
990±2.5mm
Weight: 46.3lbs (21.0kg)
11.06in
281mm
11.06in
281mm
21.65in
550mm
21.65in
550mm
65.43in
1662mm
KD200-60 P Series
AUTHORIzED DISTRIbUTOR
stABILIZER BAR