2L6/2N6/2N5/2N4
1-4-113
4300
Polygon motor phase error
tion of phase adjustment for 2
s after a BD signal is
detected.
Laser scanner unit Replace the laser scanner unit (see page 1-
5-43).
Engine PWB
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
4600
LSU cleaning motor error
After LSU cleaning motor is
driven, the ready signal does
not turn to L within 2 s.
After LSU cleaning motor is
stabilized, the ready signal is
at the H level for 1 s continu-
ously.
LSU cleaning
motor
1. Execute LSU cleaning using
Adjustment/Maintenance of the system
menu.
2. Rotate the drive gear and the cleaning
spiral by the hand and check that they
are not unusually loaded, and replace if
it is damaged.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
LSU cleaning motor and Engine PWB
(YC21)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the LSU cleaning motor.
Engine PWB
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...