2L6/2N6/2N5/2N4
1-4-152
7243
Broken developer thermis-
tor M wire
The sensor input sampling is
greater than 230.
Developer
thermistor M
1. Confirm Developing is displayed by
U139 temperature and humidity (see
page 1-3-98).
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Developer unit M and Front PWB (YC11)
Front PWB (YC2) and Engine PWB
(YC10)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. Replace the Developer unit M (see page
1-5-57).
Front PWB
Replace the front PWB
Engine PWB
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
7244
Broken developer thermis-
tor Y wire
The sensor input sampling is
greater than 230.
Developer
thermistor Y
1. Confirm Developing is displayed by
U139 temperature and humidity (see
page 1-3-98).
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Developer unit Y and Front PWB (YC15)
Front PWB (YC2) and Engine PWB
(YC10)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. Replace the Developer unit Y (see page
1-5-57).
Front PWB
Replace the front PWB
Engine PWB
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...