2L6/2N6/2N5/2N4
1-4-166
8090
DF paddle motor error
When the DF paddle motor is
driven, DF paddle sensor
does not turn on within 1 s.
DF paddle motor
1. Execute U240 Motor - Beat to check the
finisher operation (see page 1-3-134).
2. Check that the paddle can rotate.
3. Check that the drive from the motor
reaches the paddle.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF paddle motor and DF main PWB
(YC15) (4000-sheet finisher)
DF paddle motor and DF main PWB
(YC11) (1000-sheet finisher)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF paddle motor.
DF paddle sensor
1. Execute U241 Finisher - Bundle Eject
HP to check the finisher switch (see
page 1-3-136).
2. Check that the sensor and its mounting
board are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF paddle sensor and DF main PWB
(YC22) (4000-sheet finisher)
DF paddle sensor and DF main PWB
(YC20) (1000-sheet finisher)
4. Replace the DF paddle sensor.
DF main PWB
Replace the DF main PWB (Refer to the
service manual for the document finisher).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...