2L6/2N6/2N5/2N4
1-4-170
8130
DF shift release motor error
(4000-sheet finisher)
When the DF shift release
motor is driven, DF shift
release sensor does not turn
on within 1 s.
DF shift release
motor
1. Check that cancelling the maintenance
mode after executing U240 Motor - Sort
for the finisher operation check lets the
rear and forth cursors return to the home
position (see page 1-3-134).
2. Manipulate the shift guide back and forth
to check it is smoothly operable.
3. Check that the drive from the motor
reaches the shift guide front and rear.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF shift release motor and DF main
PWB (YC23)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF shift release motor.
DF shift release
sensor
1. Execute U241 Finisher - Shift Unlock HP
to check the finisher switch (see page 1-
3-136).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF shift release sensor and DF main
PWB (YC23)
4. Replace the DF shift release sensor.
DF main PWB
Replace the DF main PWB (Refer to the
service manual for the document finisher).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...