2L6/2N6/2N5/2N4
1-4-182
8320
CF adjustment motor error
(4000-sheet finisher)
When initial operation, CF
adjustment sensor does not
turn on within 2.5 s.
CF adjustment
motor1,2
1. Execute U240 Motor - Bundle Up / Down
to check the finisher operation (see page
1-3-134).
2. Manipulate the fold moving belt up and
down to check it is smoothly operable.
3. Check that the drive from the motor
reaches the fold moving belt. (Check if
the belt is bent.)
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CF adjustment motor 1,2 and CF main
PWB (YC10)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the CF adjustment motor1,2.
CF adjustment
sensor1,2
1. Execute U241 Booklet - bundle Up /
Down HP to check the finisher switch
(see page 1-3-136).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CF adjustment sensor 1,2 and CF main
PWB (YC20)
4. Replace the CF adjustment sensor1,2.
CF main PWB
Replace the CF main PWB.
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...