2L6/2N6/2N5/2N4-6
1-4-196
9520
ISC PWB error C
Main PWB
ISC PWB
1. Reinsert the connector if it its connection
is loose.
Main PWB (YC25) and ISC PWB (YC4)
2. Replace the main PWB (see page 1-5-
72).
3. Replace the ISC main PWB
4. Contact the Service Support.
9530
9540
Machine recovery error
The machine may not be
recovered or may have trou-
ble in its function with
changes of the internal data
when replacing some the
parts at the same time.
PWBs
1. Reattach the parts below in case of
replacing 2 or more of them at the same
time.
Affected parts : Memory, HDD, PWBs
* : Do not replace 2 or more of the parts
at the same time
* : And also, do not execute the follow-
ing works when replacing the above
parts.
Do not replace the drum unit or the
developing unit.
Do not replace the drum unit with the
one color for other one in the same
machine.
9940
Confidential document
guard uninstalled error
The confidential document
guard PWB is removed while
the confidential document
guard PWB is valid.
Confidential
document guard
PWB
1. Check that the confidential document
guard PWB is firmly installed and, if not,
install firmly.
2. Replace the confidential document
guard PW.
9950
Confidential document
guard PWB error
FPGA configuration error
CPU version information error
This is caused when the PWB
of a double-side scanning DP
is connected, the confidential
guard PWB is inserted, and
the harness is not correctly
connected.
Confidential
document guard
PWB
1. Replace the confidential document
guard PW.
2. Replace the main PWB (see page 1-5-
72).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...