2L6/2N6/2N5/2N4
1-4-243
3. DP-scanning second (back) page (with a reversed DP installed)
4
Adjustment of the
scanner
Check the automatic adjustment
of the scanner.
Perform maintenance mode U411,
DP FaceDown(Chart1)_All.
(see page 1-3-173)
5
DP_CIS unit
Check the location the CIS unit
is mounted.
Re-mount the CIS unit if it is hanged off.
6
DP_CIS
CIS is defective.
Replace the CIS and perform U091 and U411.
(see page 1-3-71,1-3-173)
Defective part
Check description
Corrective Action
1
Contact glass
Check whether the contact glass
is dew condensed.
If the contact glass is dew condensed, remove
the dew.
2
Mirror
Check whether the mirror is dew
condensed.
If the mirrors are dew-condensed, remove the
dew.
3
Lens
Check whether the lens is dew
condensed.
If the lens is dew condensed, remove the dew.
4
CCD sensor
Check whether the CCD sensor
glass is dew condensed.
If the CCD sensor glass is dew condensed,
remove the dew.
5
Adjustment of the
scanner
Check the automatic adjustment
of the scanner.
Perform maintenance mode U411,
Table(Chart1)_All.
(see page 1-3-173)
6
ISU
Confirm the position of the lens
and the CCD sensor.
If the lenses and the CCD sensor are
misaligned, replace the ISU and perform U411.
(see page 1-3-173)
7
ISC PWB
The ISC PWB is defective.
Replace the ISC PWB and perform U411.
(see page 1-3-173)
8
Main PWB
The main PWB is defective.
Replace the main PWB.(see page 1-5-72)
Defective part
Check description
Corrective Action
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...