2L6/2N6/2N5/2N4
1-4-254
4. DP-scanning second (back) page (with a reversed DP installed)
2
DP_SATA cable
Check the FFC cable between
the SHD PWB and I/F PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
3
DP_CIS
CIS is defective.
Replace the CIS and perform U091 and U411.
(see page 1-3-71,1-3-173)
4
Main PWB
The main PWB is defective.
Replace the main PWB.(see page 1-5-72)
Defective part
Check description
Corrective Action
1
FFC cable CCD
Check the FFC cable between
the CCD sensor and ISC PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
2
SATA cable ISC
Check the SATA cable between
the ISC PWB and main PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
3
HDD
Check the wires to the HDD in
conduction. Check the connector
for connection. Check the con-
nector pins for distortion.
1. Reinsert the connector if its connection is
loose.
2. Check the wires and connetctors, and
replace if faulty.
3. Replace the HDD or the SATA wire.
4
ISC PWB
The ISC PWB is defective.
Replace the ISC PWB and perform U411.
(see page 1-3-173)
5
CCD PWB
The CCD PWB is defective.
Replace the ISU and perform U411.
(see page 1-3-173)
6
Main PWB
The main PWB is defective.
Replace the main PWB.(see page 1-5-72)
Defective part
Check description
Corrective Action
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...