2L6/2N6/2N5/2N4
1-4-258
4
Laser scanner unit
(LSU)
Check the connection of the con-
nectors.
Or, verify conduction of the
wires.
1. Reinsert the FFC wire if it its connection is
loose.
Replace the cable if it has no conduction.
2. Replace the LSU
(see page 1-5-43)
5
Engine PWB
A control signal is not derived
from the engine PWB.
Replace the enging PWB.
(see page 1-5-80)
Defective part
Check description
Corrective Action
Summary of Contents for TASKalfa 3051ci