(1) No image appears (entirely white).
Print example
Cause of trouble
1. Defective secondary transfer bias output.
2. The secondary transfer roller is not pressurized.
Defective part
Check description
Corrective Action
1
Secondary transfer
roller
Check if the right side conveying
unit is closed.
If the conveying unit has not been closed,
check how the conveying guide is locked and
open the conveying guide once, then close.
2
Secondary trans-
fer roller pressure
motor
1. Execute U030 Press
Release to confirm that the
pressure motor for the sec-
ondary transfer roller is acti-
vated.
2. Check the connection of the
connectors.
1. Reinsert the connector if its connection is
loose.
2. Replace the motor.
3
High-voltage
PWB2
1. Check the connection of the
connectors.
2. Verify conduction of the
wires.
1. Reinsert the connector if its connection is
loose.
High voltage PWB 2 (YC1) and engine
PWB (YC8)
2. Replace the cable if it has no conduction.
3. Replace the high-voltage PWB2.
(see page 1-5-89)
4
Enging PWB
1. Check the connection of the
connectors.
2. Verify conduction of the
wires.
3. Check whether the
secondary transfer high
voltage-on signal is derived
from the engine PWB.
1. Reinsert the connector if its connection is
loose.
2. Replace the cable if it has no conduction.
3. If a signal is not obtained, replace the
engine PWB. (see page 1-5-80)
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...