2L6/2N6/2N5/2N4
1-4-277
(3) The background is colored.
(4) White streaks are printed vertically.
Print example
Cause of trouble
1. Defective intermediate transfer belt unit grounding.
2. Dirty secondary transfer roller.
Defective part
Check description
Corrective Action
1
Intermediate trans-
fer belt unit
1. Check if the belt is bleached
on its surface.
Check the value of U140
MagDC after conducting
calibration.
Increase the U140 MagDC value if the U140
MadDC value has not reached at its maximum
even though the belt is bleached on its surface.
If the MadDC increased to its maximum won't
cure, replace the intermediate transfer belt
unit. (see page 1-5-62)
2. Check if the ground tab of
the intermediate transfer belt
unit is deformed.
If the grounding tab is deformed, correct it so
that it is properly grounded.
2
Secondary transfer
roller
Check that the roller is dirty in its
entirely.
If the secondary transfer roller is dirty in its
entirely, replace.
Print example
Cause of trouble
1. Dirty the intermediate transfer belt unit.
2. Dirty the secondary transfer roller.
Defective part
Check description
Corrective Action
1
Intermediate trans-
fer belt unit
Check whether a white streak
occurs at the same position as
the smear on the intermediate
transfer belt.
1. Clean the intermediate transfer belt if it is
dirty.
2. Replace the intermediate transfer belt unit.
(see page 1-5-62)
2
Secondary transfer
roller
Check whether a white streak
occurs at the same position as
the smear on the secondary
transfer roller.
Clean the secondary transfer roller if it is dirty.
If not cured, replace the secondary transfer
roller. (see page 1-5-66)
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...