2L6/2N6/2N5/2N4-6
1-4-66
0640
Hard disk error
The hard disk cannot be
accessed.
HDD
1. If an abnormal noise is heard from the
HDD, replace the HDD.
2. Check the SATA wiring between the
HDD and the main circuit PWB for loose
connection, disconnection and
damages, and that it is connected into
the correct terminal.
Main PWB: YC1,YC27
YC2,YC32 (45/55 ppm model)
3. Replace the SATA cable.
4. Execute U024 to initialize (FULL) the
HDD (see page 1-3-32).
5. If an error is detected after executing
U024, replace the HDD.
HDD number dif-
ference
(45/ 55 ppm model
only)
1. Confirm whether the HDD number is
correct in U024_Composition and
change it if different (see page 1-3-32).
HDD 1piece: Single
HDD 2pieces: Multi
Lack of HDD
capacity
(45/ 55 ppm model
only)
1. Confirm the total capacity of the HDD if it
is more than 320GB.
Change the HDD or add it in case of
lacking in capacity.
Main PWB
Replace the main PWB (see page 1-5-72).
0650
FAX image DIMM check
error
A fax image DIMM which was
used with another machine is
installed.
FAX DIMM.
1. Confirm that a used FAX image DIMM
was used instead of the FAX image
DIMM contained in the FAX system.
2. If a DIMM that was used with other unit
has been installed, execute
maintenance mode U671 - Recovery
FAX DIMM.
3. Check whether the Fax DIMM is
properly inserted into the socket on the
main PWB.
4. Replace with a new FAX image DIMM.
Main PWB
Replace the main PWB (see page 1-5-72).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...