2KN/2KP
1-4-36
C2720
PTC cleaning motor error
• LOCK signal remains high for 1 s,
200 ms after the PTC cleaning motor
has turned on.
Poor contact in the
drive motor con-
nector terminals.
Check the connection of connector YC5 on
the engine PWB. Reinsert the connector.
Also check for continuity within the connec-
tor cable. If none, remedy or replace the
cable.
Defective PTC
cleaning motor
rotation control cir-
cuit.
Replace the PTC cleaning motor.
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective engine
PWB.
Replace the engine PWB.
C3100
Scanner carriage problem
• The home position is not correct when
the power is turned on or at the start of
copying using the MP tray.
Defective scanner
PWB.
Replace the scanner PWB and check for
correct operation.
Defective scanner
home position
switch.
Replace the scanner home position switch.
Defective scanner
motor.
Replace the scanner motor.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC2,
YC5 and YC10 on the scanner PWB and the
continuity across the connector terminals.
Repair or replace if necessary.
Defective mirror
flame, exposure
lamp or scanner
wire.
Check if the mirror flames and exposure
lamp are on the rail. And check the scanner
wire winds correctly.
C3200
Exposure lamp problem
• Check the CCD input value for the
lighting status of the exposure lamp
500 ms after the exposure lamp is lit
and the carriage is moved to the shad-
ing position. If the exposure lamp does
not light, a further 100 ms later, check
the CCD input. The exposure lamp
does not light after 50 retries.
Defective scanner
PWB.
Replace the scanner PWB and check for
correct operation.
Defective exposure
lamp or inverter
PWB.
Replace the exposure lamp or inverter
PWB.
Incorrect shading
position.
Adjust the position of the contact glass
(shading plate). If the problem still occurs,
replace the scanner home position switch.
Poor contact of the
connector termi-
nals.
Check the connection of connectors YC3,
YC4 and YC5 on the scanner PWB, YC5,
YC6 and YC8 on the SHD PWB and YC1,
YC2 and YC3 on the CCD PWB, and the
continuity across the connector terminals.
Repair or replace if necessary.
Defective CCD
PWB.
Replace the CCD PWB and check for cor-
rect operation.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Summary of Contents for TASKalfa 620
Page 1: ...SERVICE MANUAL Published in August 2009 842KP112 2KPSM062 Rev 2 TASKalfa 620 820 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 144: ...2KN 2KP 1 3 106 This page is intentionally left blank ...
Page 308: ...2KN 2KP 1 5 88 This page is intentionally left blank ...
Page 412: ...2KN 2KP 2 3 60 This page is intentionally left blank ...
Page 435: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR SIDE FEEDER ...
Page 442: ...INSTALLATION GUIDE FOR LARGE SIZE SIDE FEEDER ...
Page 460: ...INSTALLATION GUIDE FOR DOCUMENT FINISHER ...
Page 475: ...INSTALLATION GUIDE FOR CENTERFOLD UNIT ...
Page 490: ...INSTALLATION GUIDE FOR MULTI JOB TRAY ...
Page 501: ...INSTALLATION GUIDE FOR PUNCH UNIT ...
Page 512: ...INSTALLATION GUIDE FOR STOPPER GUIDE ...
Page 515: ...INSTALLATION GUIDE FOR PRINTING SYSTEM ...
Page 518: ...INSTALLATION GUIDE FOR SCAN SYSTEM ...
Page 520: ......
Page 521: ......