(1) Detaching and refitting the exposure lamp
Follow the procedure below to replace the exposure lamp.
Fitting requires following parts
Band (P/N: M21AH010)
Procedure
1. Remove two screws of hinge retainer at the
rear side of the left hinge and then remove
the retainer from DP.
2. Open DP until it becomes perpendicular.
Figure 1-5-55
3. Remove two screws and then remove the
upper right cover.
4. Remove the contact glass.
Figure 1-5-56
5. Move the mirror 1 frame to the notch of
machine center.
* When moving the mirror 1 frame, do not
touch the exposure lamp.
Figure 1-5-57
Hinge retainer
DP
Upper right cover
Contact glass
Mirror 1 frame
Summary of Contents for TASKalfa 620
Page 1: ...SERVICE MANUAL Published in August 2009 842KP112 2KPSM062 Rev 2 TASKalfa 620 820 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 144: ...2KN 2KP 1 3 106 This page is intentionally left blank ...
Page 308: ...2KN 2KP 1 5 88 This page is intentionally left blank ...
Page 412: ...2KN 2KP 2 3 60 This page is intentionally left blank ...
Page 435: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR SIDE FEEDER ...
Page 442: ...INSTALLATION GUIDE FOR LARGE SIZE SIDE FEEDER ...
Page 460: ...INSTALLATION GUIDE FOR DOCUMENT FINISHER ...
Page 475: ...INSTALLATION GUIDE FOR CENTERFOLD UNIT ...
Page 490: ...INSTALLATION GUIDE FOR MULTI JOB TRAY ...
Page 501: ...INSTALLATION GUIDE FOR PUNCH UNIT ...
Page 512: ...INSTALLATION GUIDE FOR STOPPER GUIDE ...
Page 515: ...INSTALLATION GUIDE FOR PRINTING SYSTEM ...
Page 518: ...INSTALLATION GUIDE FOR SCAN SYSTEM ...
Page 520: ......
Page 521: ......