2KN/2KP
2-3-4
TAB
1
AC LIVE IN
I
120 V AC
AC power input
Connected
to the AC
inlet and
front cover
switch
220-240 V AC
2
AC NEUTRAL
IN
I
120 V AC
AC power input
220-240 V AC
3
AC LIVE OUT
O
120 V AC
AC power output for front cover switch
220-240 V AC
4
AC NEUTRAL
OUT
O
120 V AC
AC power output for front cover switch
220-240 V AC
5
AC NEUTRAL
IN
I
120 V AC
AC power input (via front cover switch)
220-240 V AC
Connector
Pin No.
Signal
I/O
Voltage
Description