29
⑩
Set each items of the judging parameter.
※
When fixing the cap tip setting, change by clicking “up”.
CAUTION
: When changing, the judging parameter will be formatted.
[Diameter Setting]
Maximum, Minimum setting
:
If in between the set value, OK judge
From the 2 measured length, select the judgment pattern.
No Evaluation
:
Diameter judge will be always OK
Either within limit
:
OK judge when either of the tips passes the limit
(
Default
)
Both within limit
:
OK judge when both tips passes the limit
[Area of BlackREM]
Outer dotted line
(
Judgment objected to totalarea of the tip top
)
Black REM. Diameter
:
Select the area for judging the blackREM the tip top.
Black REM. Threshold Value
:
Maximum BlackREM permissible in a selected area
Inner dotted line
(
Judgement objected to the center of tip top
)
Center BlackREM. Diameter
:
Select the area for judging the blackREM of the center of the tip top.
Center BlackREM. Threshold Value
:
Maximum BlackREM permissible in a selected area
Summary of Contents for TM01-KP-00A