6.000A
10.00A
600.0μA
6000μA
60.00mA
600.0mA
6.000A
10.00A
600.0Ω
6.000kΩ
60.00kΩ
600.0kΩ
6.000MΩ
60.00MΩ

ACA

Resistance

Ω

±1.5%rdg±5dgt (50 / 60Hz)

±1.8%rdg±5dgt (40〜400Hz)
±1.2%rdg±3dgt (50 / 60Hz)

±1.5%rdg±3dgt (40〜400Hz)

Overload protection: 600V DC or AC

rms   Impedance: 10MΩ

0.1V or less is outside the accuracy

Crest factor(CF): 3.0 or less

Overload protection: 0.8A/600V

Overload protection: 10A/600V

Overload protection: 0.8A/600V

Crest factor(CF): 3.0 or less

Overload protection: 10A/600V

Crest factor(CF): 3.0 or less

Overload protection: 600V DC or AC rms.

±1.5%rdg±5dgt (50 / 60Hz)

±1.8%rdg±5dgt (40〜400Hz)

±1.2%rdg±3dgt

±2.0%rdg±5dgt

±1.5%rdg±4dgt(50/60Hz)

±2.0%rdg±4dgt(40〜1kHz)

Display read approximately forward voltage of diode

Built-in buzzer sounds if resistance is less then 100Ω

Description

Ranges

It  can  not  display  bar  graph  on  diode

range

Overload protection: 600V DC or AC rms.

Note

Forward DC current approx.0.4mA 

Reversed DC voltage approx.2.8V
Open circuit voltage approx.0.5V

Test condition

Note

It  can  not  display  bar  graph  on

capacitance range

It  can  not  display  bar  graph  on

frequency range

Overload protection: 600V DC or AC rms

Accuracy

±3.0%rdg±10dgt

±2.5%rdg±5dgt

±5.0%rdg±10dgt

±0.1%rdg±5dgt

±2.0%rdg±2dgt  Frequency lower then

10kHz Sensitivity: sine wave 0.6V rms

±2.2%rdg±5dgt(50/60Hz)

±2.5%rdg±5dgt(40〜1kHz)

±1.0%rdg±2dgt

±2.0%rdg±3dgt

0〜600V

(4 Auto ranging)

0〜6000μA

(2 Auto ranging)

0〜600mA

(2 Auto ranging)

0〜6000μA

(2 Auto ranging)

0〜600mA

(2 Auto ranging)

0〜10A

(2 Auto ranging)

0〜60MΩ

(6 Auto ranging)

0〜10A

(2 Auto ranging)

6.000V

60.00V
600.0V

600V

600.0μA
6000μA
60.00mA
600.0mA

ACV

DCA

Function

Capacitance

Frequency

Ranges

40.00nF
400.0nF
4.000μF
40.00μF
400.0μF
4000μF
10Hz
100Hz
1000Hz
10kHz
100kHz
1000kHz
10MHz

DUTY

Measuring range

0.01nF〜4000μF

(6 Auto ranging)

1Hz〜10MHz

(7 Auto ranging)

Input which can be

measured : Voltage :

〜1MHz = more than 1.5V

1〜10MHz = more than 2V

0.1〜99.9%

(Pulse width/Pulse period)

Summary of Contents for KEW 1012

Page 1: ...KEW 1012 AUTO RANGE DIGITAL MULTIMETER KYORITSU ELECTRICAL INSTRUMENTS WORKS LTD INSTRUCTION MANUAL...

Page 2: ...n the manual DANGER is reserved for conditions and actions that are likely to cause serious or fatal injury WARNING is reserved for conditions and actions that can cause serious or fatal injury CAUTIO...

Page 3: ...quipment which is supplied power from a distribution board and cable run from a distribution board to an outlet 2 Features This instrument KEW1012 is a Digital Multimeter which designed for making mea...

Page 4: ...600V DC or AC rms Note Forward DC current approx 0 4mA Reversed DC voltage approx 2 8V Open circuit voltage approx 0 5V Test condition Note It can not display bar graph on capacitance range It can not...

Page 5: ...ss than 90 Insulation Resistance It should be more than 100M DC1000V between electrical circuit and enclosures Withstand Voltage It should be more than AC3700V for one minute between electrical circui...

Page 6: ...the instrument case 6 1 1 DC Voltage Measurement DCV 1 Insert the black test lead plug into the COM terminal and the red test lead plug into the V Hz terminal 2 Set the Function Selector Switch to pos...

Page 7: ...e circuit 5 Power on the circuit under test 6 Measured value is indicated on the display If you connect the test leads the other polarity symbol is indicated on the display 6 2 2 DC Current Measuremen...

Page 8: ...e sure that the O L symbol is indicated on the display at this bout then short the test lead tips and check 0 is indicated on the display 3 Connect the test leads to both ends of the resistance under...

Page 9: ...ed on the display Measuring unit nF uF is automatically chosen and indicated due to the measured value Note It may take some time according to the measuring capacitance Measuring capacitance 4uF Measu...

Page 10: ...uto ranging there are following 2ways 1 Press RANGE Key for 2seconds 2 Change to the other functions 7 4 REL Key The difference between measured values can be indicated on the display at each ACV DCV...

Page 11: ...e to remove test leads from the instrument when opening the battery cover in order to replace batteries and fuses 9 1 Battery replacement 1 Remove test leads from the instrument 2 Remove the holster f...

Page 12: ...92 1825C KEW 1012 Kyoritsu reserves the rights to change specifications or Designs described in this manual without notice and without obligations DISTRIBUTOR...

Reviews: