background image

MW29

Do not mark on the model and other 

components with pen nor leave printed 

materials contacted on surface.

Ink marks on the models cannot be 

removed.

Caution

Oral Care Simulator Advanced 

Contents

● Before You Star

Set Includes

Manufacturerʼs Notes

● Training Session

● After Training

Oral Care
Suction

Preparation

P.2

P.3

P.11〜P.12

P.6〜P.7

P.3〜P.4

P.8〜P.10

P.10

● Introduction

P.1

P.5

Checking the Connections
Setting up the Head Manikin
Changing Dentures

Setting of Patient Conditions

Instruction

Manual

Summary of Contents for MW29

Page 1: ...ed Caution Oral Care Simulator Advanced Contents Before You Star Set Includes Manufacturerʼs Notes Training Session After Training Oral Care Suction Preparation P 2 P 3 P 11 P 12 P 6 P 7 P 3 P 4 P 8 P 10 P 10 Introduction P 1 P 5 Checking the Connections Setting up the Head Manikin Changing Dentures Setting of Patient Conditions Instruction Manual ...

Page 2: ......

Page 3: ...and product from deforming Constituent in the simulated residue may separate At times some constituent in the simulated residue such as alcohol may be observed though this does not affect the quality and performance of the product The manikin skin may be cleaned with a wet cloth if necessary using mildly soapy water or diluted detergent Even if color on its surface might be changed across the ages ...

Page 4: ...nsure that you have all components listed below Sponge tipped swabs 1 1 1 2 1 1 1 1 a b c g h i f d e 1 Head neck manikin Simulated residue is consumable Base Normal denture Denture with tooth disease Simulated residue Mirror Toothbrush Denture brush j Case for denture 1 Instruction manual ...

Page 5: ...t the place where to set the head manikin and put it there Press down the suction cup at the head side onto the table top Then turn the two dials at the neck side clockwise to anchor Table top training Prepare a table with smooth surface Securing the Head Neck Manikin 3 To disengage release the suction cup at the head side by lifting up the plate with finger and then turn the dials counter clockwis...

Page 6: ...red place Spine Fowlerʼs Sitting 2 Rotate the head to left or right to adjust the position 1 Put the manikin on the bad and adjust the bedʼs angle Support the manikin securely in place by a pillow or by an assistant when necessary Training on the bed Caution To rotate the head be sure to hold the head with both hand Be careful not to hold the neck area so as not to pinch the fingers ...

Page 7: ...to the gum and press the denture When setting the upper denture first fix the front teeth and then fit the back teeth To attach the lower denture first put the denture in place to surround the tongue then press down the front teeth and finally fit and press the back teeth Caution 2 To remove the dentures first lift and disengage the back teeth Removal Be careful not to catch the manikinʼs tongue under th...

Page 8: ...nded The endtracheal tube can be set by hand without using the laryngoscope or stylet 2 Remove the dentures Insert the finger into the manikinʼs oral cavity and feel to locate the glottis 3 Insert the endotracheal tube into the airway Insert the tip of the tube into the glottis by the finger 4 Holding the tube with the finger insert the tube into the airway Oral Cavity Tangue Glottis Endotracheal Tub...

Page 9: ...he tracheostomy opening Lubricate the tube and the inside of trachea Since the tracheostomy opening is already made at times some types or sizes of cannula may not fit well Tracheostomy Tube II internal diameter 8 0mm external diameter11 0mm is available as an optional part Caution Be sure to use the authentic Kyoto Kagaku lubricant for training which is available as an optional part Do not use gel...

Page 10: ...h oral problems Normal Tooth Disease Apply the simulated residue A tooth without neighboring teeth Apply the simulated residue Stump of a tooth A stump without dental crown Crowding Gingival Recession Non Dental Problem Dental Problem Dental and Oral Problems 2 Apply the simulated residue on the teeth and or the tongue to perform observation Observation of food residue and coated tongue Whenever n...

Page 11: ...to practice brushing and cleaning 2 1 Care of the Dentures Do not use tooth paste as it may damage the parts Caution After brushing and cleaning apply water wash fluid to the oral cavity and clean while suction ing excess liquid In case that the suctioning is unsuccessful excess liquid flows into the mini bottles to indicate that liquid flows into bronchi or esophagus Practice how to remove and attac...

Page 12: ...ession Oral Care Suction Removal of Tongue Coating 1 Apply the simulated residue on the tongue to practice cleaning using a sponge brush or a tongue brush Oral Care Parotid Gland Submaxillary Gland Sublingual Gland 1 Procedures of nasal oral and tracheostomy suction can be simulated Suctioning Suction ...

Page 13: ...Training After Training 1 Remove all medical instruments medical tape and the dentures see page 5 In case that the simulated residue is used remove it completely and dry the parts well 2 Remove the two screws which connect the head manikin and the base by turning counter clockwise Then remove the head manikin from the base Note ...

Page 14: ... the base and fix them together with two screws Turn the screw clockwise to fasten Then replace the plug to the tracheostomy opening 7 Store the assembled head in the storage bag 1 4 Remove the plug for tracheostomy opening Wash inside with running water Then dry the parts well After Training ...

Page 15: ......

Page 16: ...nt for training model tracheostomy tube Ⅱ Lubricant for Training Model Tracheostomy Tube II Consumables Optional Parts Caution The contents of the instruction manual are subject to change without prior notice No part of this instruction manual may be reproduced or transmitted in any form without permission from the manufacturer Please contact manufacturer for extra copies of this manual which may ...

Reviews: