background image

1. 

Screw the right arm to the shoulder.

Before Training

Preparation

1

Right Arm Installation 

2. 

Remove the body skin. (The skin is fixed by six braces)

3. 

Remove the lung and rib and remove the umbilical part.

Summary of Contents for NCPR Simulator

Page 1: ... with pen or leave any printed materials contacted on surface Ink marks on the model cannot be removed Right Arm Installation Simulated Blood making Umbilical blood preparation Injection of the Stomach Fluid Water Injection of the Simulated Blood Airway Management Umbilical Catheterization NG OG Tube Feeling Airway Suction CPR Training Positioning keeping Assessment of Anterior Fontanel Drainage o...

Page 2: ......

Page 3: ...rtion Ligation with clip or string Placement Umbilical Catheterization NG OG Tube Feeding Airway Suction CPR Airway Management Training Positioning Keeping Assessment of Anterior Fontanel Do not mark on the model and other components with pen or leave any printed materials contacted on surface Ink marks on the model cannot be removed Handle the manikin and the components with utmost care at all ti...

Page 4: ...wab type Configuration Configuration 2 A C D Set Includes Before your first use ensure that you have all components listed below Before You Start Set includes a d e Bronchi Stomach Esophagus Umbilical Cord Blood storage bottle Umbilical Cord Unit Ribs Lung Oral Cavity b c d e a b c ...

Page 5: ... Screw the right arm to the shoulder 3 Before Training Preparation 1 Right Arm Installation 2 Remove the body skin The skin is fixed by six braces 3 Remove the lung and rib and remove the umbilical part ...

Page 6: ...bilical part Open it to fill with the umbilical blood Install the umbilical bottle into the umbilical part 1 Pour 1000mL of water into the plastic beaker Put the simulated blood swab type into the beaker and stir the water sufficiently to prepare the simulated blood Take care not to drop simuleted blood on clothes as simuleted blood stains can be very difficult to remove Caution ...

Page 7: ...n hole first and put the body skin on the body to fix by six braces 5 Before Training Preparation 3 Umbilical blood preparation 4 Injection of the Stomach Fluid Water 1 Connect the syringe to the connector under infra axillary of the left side of body to inject the stomach fluid The volume is approximately 5ml Remove the syringe when finished ...

Page 8: ...anging Palpating to assess the anterior fontanel Training Positioning keeping Assessment of Anterior Fontanel 2 Umbilical Catheterization Provides training for routine procedure of umbilical catheterization for both operator and assistant Omphalotomy Catheter insertion Ligation with clip or string Placement Recommened Catheter Size 16G 30cm ...

Page 9: ... placement by dressing Spray the attached lubricant to the catheter nasal and oral cavity of model before practice Recommended catheter size 5Fr 4 Recommended catheter size 5Fr Airway Suction Use the lubricant to spray the catheter nasal and oral cavity of model before practicing Training for the nasogastric and orogastric suction 5 CPR Training for chest compression Airway Suction CPR ...

Page 10: ...tubation Spray the lubricant into the oral cavity and device before intubation practice Tube 2 0 3 0 mm Blade 0 Training for the procedure of intubation with laryngoscope Training for the assessment of intubation to the esophagus or one lung or two lung intubation Bag Valve Mask ventilation ...

Page 11: ... it 2 Put the edge of mask on the gap of posterior head to cover the head when installing the face mask 3 Refer to Preparation page regarding body skin replacement 1 Remove the umbilical part and put out the umbilical bottle to drain the simulated blood After that clean up the bottle and dry it up 2 Connect the empty syringe to the connector under infra axillary of the left side to draw the stomac...

Page 12: ...ce Ink marks on the model cannot be removed 1 mask mask 1 chest skin chest skin 4 umbilical cord umbilical cord 11400 010 11400 020 11400 030 For inquiries and service please contact your distributor or KYOTO KAGAKU CO LTD Consumable parts code name 1 lubricant 1 lubricant 11229 050 11388 400 code name Simulated blood Simulated blood Swab type a set of 10 ...

Reviews: