84
6-4-5. Level Passed Way (Trigger Slope)
Sets the way that the measured value passes the “Passed Level” as a trigger condition.
・
Rising:
Passes from the lower level of the Passed Level to higher level.
・
Falling :
Passes from the higher level of the Passed Level to lower level.
・
Both:
Passes from the higher level of the Passed Level to lower level and from the lower level of the Passed
Level to higher level.
The
key is invalid and displayed in gray when selecting the “
Auto Mode
.”
<Setting Range>
Rising, Falling, Both
<How to operate>
1) Press the
key on the “
Wave Display Setting (1/2)
”
window.
2) Press the
key on the “
Wave Display Setting (2/2)
”
window.
3) Press the target key and
key for registration.
6-4-6. Hold Time of Wave
Sets a time that holds the previous waveform (time for clearing the previous waveform to complete) from the end of
one window to display the next waveform when selecting the “
Auto Mode
” in the “
Start Mode of Wave
” window.
The
key is invalid and displayed in gray when selecting the “
Normal Mode
” and “
Single Mode
.”
<Setting Range>
0.0
~
99.9(sec)
<How to operate>
1) Press the
key on the “
Wave Display Setting (2/2)
”
window.
2) Input a setting value with the numeric keyboard and press the
key for registration.
1 / 2
The level that measured value
passes for satisfying trigger
condition is set.
Next
1000.00kN
Auto Mode
0.00kN
The start and end point of Y-
axis are set.
The mode to start the wave
display is set.
Y-axis Setting
Start Mode of Wave
Passed Level
Wave Display Setting
The end point of X-axis(time)
is set.
10.0sec
Return
Measure
X-axis Setting