STRATUS Multi-Deck Display Case
17
Electrical Connections—General
WARNING! Ensure the kickplate does not come in contact with the case electrical wiring. Live electrical wiring that
comes in contact with the case is a shock hazard that may cause severe injury or death by electrocution.
WARNING! Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical
component. This includes, but is not limited to items such as fans, heaters, thermostats, and light bulbs. Failure to
disconnect the electrical power may result in personal injury or death.
CAUTION: Failure to properly install electrical wiring and control wiring as per wiring diagram(s), defrost settings,
and temperature set-points may result in operational issues such as the following: increased thermal load, high prod-
uct temperature, coil icing, product frosting, and external sweating.
Shelf Light Installation—T8 Shelf Lights
•
Make sure plugs are FULLY SEATED before applying power.
•
Due to the nature of rapid start ballasts, it is highly recommended that lights are plugged in BEFORE power
is applied to cases, and BEFORE cases are at a steady rate operating temperature.
•
If lights flicker when first started up, disconnect power to lights, verify plug is fully seated, and then ensure
pow
er is off for at least 20 seconds before re-applying power.
CAUTION: Failure to follow these instructions may result in premature bulb and ballast failure.
NOTE: Failure to follow installation instructions may void standard warranty.
Electrical Termination
There are three field power supply connections consisting of: (A) case power supply; (B) condensing unit power
supply (C) defrost water evaporation pan power supply. (see Wiring Diagrams in this section)