G O M - 영 문
42
Electricity Line Construction
230V~50Hz
Electrical connection
y
The boiler has to be connected to the electrical
installation by an “
X”
type power cable without plug.
y
The power cable must be connected to a 230V~
50Hz main supply with correct sequence Line-
Neutral-Heart.
y
The main power supply must be also equipped
with a multi-pole circuit switch, with a contact
opening gap of at least 3mm.
y
The electrical safety of the unit is guaranteed
when correctly connected to an effective and
efficient earth system as specified in the current
safety standard.
y
The boiler is designed with IPX4d protection
rating.
y
The power cable must be laid as shown in the
figures.
y
For safety reason, please take the heart cable at
least 2cm longer than the Line and Neutral cable
y
In the event of power cable replacement, please
contact a qualified electrical technicians.
y
At the end of any cable installation or substitution,
please, squeeze the press cable in the boiler.
y
For the main power supply of the boiler, never
use plugs, adapters, multiple sockets or extension
leads.
CAUTION
Boiler pipes must never be used to heart the
electrical or the telephone lines.
4