Please install supply ventilation and
ventilation.
y
Lack of ventilation may cause incomplete
combustion due to oxygen shortage and if
the ventilation fan malfunctions, incomplete
combustion may result and exhaust gas
may seep into the inside causing carbon
monoxide poisoning.
y
The basic criteria to follows is to have an
opening of at least 6 square centimeter per
each kW of input capacity.
y
For the choice of the correct dimension of
the holes of ventilation please follows the
national and the local laws and standards.
For B33 installation type, intake or exhaust
flue should be installed in a location where
there is a good ventilation from the outside
and there is no seepage of exhaust gas
into the inside of the house.
y
Please follows the instruction supplied in the
following paragraph.
y
It is possible to cause incomplete combustion
due to lack of oxygen and presence of
exhaust gas and exhaust gas seepage may
cause Carbon Monoxide poisoning.
Please install so that the intake side or
the exhaust side of the supply/exhaust
pipes are not inside of the wall.
y
If the intake / exhaust openings are inside
of the wall, there may be incomplete
combustion due to lack of oxygen causing
Carbon Monoxide poisoning.
Forced Exhaust Type Pipe Construction
(TYPE B33)