G O M - 영 문
58
The TOTAL MAXIMUM LENGTH (1)
+
(2) of this configuration is 21.70m
CHOICE OF THE DIAPHRAGM
Flue system length Up to 2.80m
Between
2.80m
–
10.50m
Between
10.50m
–
16.10m
Between
16.10m
–
21.70m
131GOM
–
161GOM
φ
41mm
φ
48mm
φ
52mm
Without
201GOM-251GOM
φ
48mm
φ
52mm
Without
y
In order to be considered C13 type, the terminals for the air intake and for the
exhaust outlet have to be included in a square of 50cm.
y
It is also possible to instal the terminal at a longer distance than this or on a different
wall.
y
In order to avoid the look out of the boiler, it
’
s forbidden to istall the intake and the
outlet of the flue system on the wall placed to the opposite side of the house.
y
With the above C13 flue system type(80/80 separate and 60/100 concentric)
please
NEVER
close the terminal part with any object(like, for exampple, plastic
bag or other devices during the painting of the exthernal side of the wall) that may
force the exhausts to return in to the air duct.
y
On the contrary iit exists the concrete risk of explosion of the sealed chamber of the
boiler.
Horizontal separate flue system 80/80mm
–
Type C13