The terminals for the exhaust have to respect certain minimum distances from the
elements of the building as showed in the following prospect.
DESCRIPTION
mm
Under the window
A
600
Under an air opening
B
600
Under a eaves
C
300
Under a balcony
D
300
From a near window
E
400
From a near air opening
F
600
From a discharge tube
G
300
From a building corner
H
300
From a recess
I
300
From the ground or other floor
L
2,500
Between two terminal in vertical
M
1,500
Between two terminal in horizontal
N
1,000
From a facing wall without any air opening or any other terminal in a
radius of 3m
O
2,000
From a facing wall with air opening or other terminal in a radius of 3m
P
3,000
Position of the terminal for the exhausts