G O M - 영 문
67
y
The most important fault are detected by the PCB and showed trough the display
interface.
y
When a fault occur, the digits start to blink.
y
The left digit shows the E letter (As Error Code).
y
The 2
nd
and 3
rd
right digits show one of the following numbers :
Error Code
Problems
E02
Primary water flow failure
Pump = ON and Flow switch = OFF
E03
Lockout for ignition failure
E05
Heating sensor interrupted
E06
Heating sensor short circuit
E07
Domestic hot water sensor interrupted
E08
Domestic hot water sensor short circuit
E09
Fan failure
E10
Air pressure switch failure
E13
Primary flow switch failure
Pump = OFF and Flow switch = ON
E15
Main supply frequency error
E16
Lockout for high limit switch
y
When the boiler is in working mode ON, pressing the button for less than 0.5
seconds it
’
s possible to look, on the display, at the following parameters in
sequence :
No.
Parameter
Display
1
Domestic hot water temperature
°
C digits
2
Central heating temperature
°
C digits
3
External temperature
(1)
°
C digits
4
K factor
(1)
digits
5
Return to the standard visualization
(1) The external temperature and the K factor are shown if the external sensor is present. A
complete explanation of the user procedure is written in the
“
user manual
”
chapter.
Fault Codes
User menu
(Synthesis)