G O M - 영 문
69
Change of gas
If it
’
s necessary to convert the boiler for different
type of gas than what specified on the data plate,
the specific gas kit must be requested for a
quick and easy conversion.
Conversion of the gas type must be done by a very
skilled engineer authorized by the manufacturer.
The gas conversion may be done following these
operations :
* Replace the nozzles of the main burner respecting
the information included in the following table.
* Adjust the gas valve from the current gas to the
new gas, following the below procedure:
y
Connect the pressure gauge to the gas probe
(1) in order to measure the burner gas pressure.
(screw out a couple of turn the inside screw)
y
Remove the transparent plastic cup.(2)
y
With the modulator powered to the maximum
(for example opening the DHW tap to the
maximum) screw or unscrew the brazing screw
(3)(with a 10mm spanner) up to the burner gas
pressure reach the value specified in the table.
y
WARNING
y
For the boiler adjusted for LPG Gas, Group 3+
the screw(3) has to be turned on up to the end
of its stroke.
y
With the modulator not powered(for example taking away the fastener connection)
screw or unscrew the red plastic screw(4) up to the burner gas pressure reach the
value specified in the table.
y
Put back the transparent plastic cup on the modulator.
11