Checkpoints before Making Repair Work Order
In case of any malfunction, before calling an A/S center or dealer for repairs, please check the following items.
If the display shows some error code number, after treating each of the status, restart the unit
(switch on the unit
again and a minute after the inspection occurs, you must press restart in order to start the unit).
When the unit fails to restart then please contact the nearest service center.
Condition
Cause
Countermeasure
Fuse is out.
Please call for inspection.
☎
Power is out.
Please wait until electricity comes
back on.
☜
Bad power connection.
Please call for inspection.
☎
NO symbols and
Digits appear on
the display
Bad display connection.
Please call for inspection.
☎
Heating temperature
is indicated but the
boiler is not working
Boiler temperature setting is low.
Increase the boiler temperature
setting.
☜
No water in the heating ducts.
Please replenish the heating water.
☜
No water flow in the heating ducts.
Please open eventual radiator valve
Please clean the heating filter.
☎
Display shows error
code E13
Circulation pump malfunction.
Please call for inspection.
☎
Display shows error
code E09
The fan doesn’t run.
Please call for inspection.
☎
Boiler
doesn’t
start
Display shows error
code E10.
Ignition is not done
and fan continuous
to operate.
Air supply or exhaust ducts are
blocked.
Chimney is blocked.
Air pressure switch is malfunctioning.
Please call for inspection.
☎
Supply gas pressure is low or supply
is not adequate.
Please call for inspection.
☎
Improper flame detection.
Please call for inspection.
☎
Gas shut-off valve is closed.
Please open the Gas shut-off valve.
☜
After starting, flame doesn’t
start and stops immediately,
the display shows error code
E03 and the symbol
appears on the display
Improper ignition spark.
Please call for inspection.
☎
Heating pipe valve is closed or
pipes are blocked.
Please clean the heating filter
(see page 21).
Open the heating pipe valve.
☜
There is too much air inside of the
heating pipes.
Open the air release valve inside
the distributor to remove all the air
then close the valve (see page 11).
☜
Boiler is operating normally,
but heating is not done
properly.
Heating pipe is leaking.
Please call for inspection.
☎
Water pressure is low.
Please call for pressurize device
installation.
☎
Hot water line is blocked.
Please call for inspection.
☎
Hot water flow switch is
malfunctioning.
Please call for inspection.
☎
Boiler is operating normally,
but hot water is not available.
Three-way valve is malfunctioning.
Please call for inspection.
☎
Boiler pressure keeps falling.
There is a leak in the pipes.
Please call for inspection.
☎
Supply pipes are not installed
correctly.
Please call for inspection.
☎
During the ignition and
combustion, there is a large
noise.
Supply pipes are blocked.
Please call for inspection.
☎