k c a - 영 문
54
In the tunnel portion where the pipe goes
through the wall, it must be completely
airtight in order to prevent any exhaust
gas from re-entering inside
.
If the exhaust gas enters inside, it may cause gas
poisoning.
When the exhaust flue system goes
through combustible wall, or ceiling, cover
with at least 20mm of non-combustible
materials and keep at least 50mm of
space.
Please install so that the intake side or the
exhaust side of the supply/exhaust pipes are
not inside of the wall.
If the intake/exhaust openings are inside of the
wall, there are may be incomplete combustion
due to lack of oxygen causing Carbon Monoxide
poisoning.
Please install so that the rain cover
protection is placed in the upper side.
If the cover is not correctly placed, the rain can
enter in to the boiler through the boiler flue system.
The connection portion of the exhaust pipe
must be completely airtight.
In case of leaks, exhaust gas leakage may cause
carbon monoxide poisoning.