Emergency stop information
- EMERGENCY STOP ON bar display POP-UP and machine is stopped if EMERGENCY STOP button
is pressed or concerned it.
1. EMERGENCY STOP ON : In case of EMERGENCY STOP button is pressed.
2. MAGNETIC OCR TRIP : Over current in the panel is tripped.
※ Open panel back side cover and release trip manually.
3. SAFETY SENSOR #1~3 : In case of Safety Sensors are installed.
※ People or material is interrupted sensor.
4. TRANSFER/BELL POSITION CHECK : Proximity Switch is touched when Transfer forward or
backward, or Bell Limit Proximity Switch (Backside) is touched.
※ Pole is not moving unless Bell is moving.
5. WATER TEMPERATURE HIGH : Cooling water temperature is over the temperature set up by
TEMPERATURE CONTROLLER on the panel.
※ Waits temperature of cooling water to be cool down, or replace coolant water.
6. WELDER TEMPERATURE HIGH : Welder temperature is over 75。C (167 F)