75
to operate inconsistently and cause poor combustion. Only qualified
technicians with proper training and equipment should make any
mechanical adjustments.
Voltage must be between 10.5 volts to 13.5 volts at the furnace during
operation. Below 10.5 volts the furnace will shut down. Both high and low
voltage places excessive wear on the motor and brushes.
Any mechanical adjustments, such as electrode adjustments, should be
performed by a qualified service technician.
Range and Oven Top Burner
Several types of cooking appliances are used in KZRV products. A drop-
in stove with 2 or 3 burners, a standard oven with 3 top burners, or an
oven with top burner piezo lighter. These appliances operate with
propane gas ONLY. NEVER use natural gas or butane.
Before attempting to light the stove, top burners or oven, BE SURE the
valve on the propane container is open. This 3 burner range features blue
LED lights on each burner knob. Fuse for the lights is located behind the
switch on converter and fuse panel.
Operating Instructions
Lighting Top Burners
Match Lighting
1. Before lighting, check to make sure the control knobs are turned
to off position.
2. Check that the main gas tank valve is open.
3. Turn the appropriate
burner knob counterclockwise to “LITE”
position.
NOTE:
Do not attempt to light more than one burner at a time.
4. Immediately strike and place a burning long wooden match (or
the match extension or a butane lighter with extension) through
the spaces in the grate near the ports of the burner to light the
burner.
5. Repeat steps 3 and 4 to light the other burners as needed.
6. Push and turn the burner control knob to adjust the flame to
desired level.
Electronic Ignition
1. Before lighting, check to make sure the control knobs are turned
to the off position.
2. Check that the main propane tank valve is open.
3. Turn the appropriate burner knob counterclockwise to the LITE
position.
NOTE:
Do not attempt to light more than one burner at a time.
4. Turn the ignition knob clockwise repeatedly until burner lights.
5. Repeat steps 3 and 4 to light the other burners as needed.