SKY899
Installation Manual
Page B-4 - Appendix B
009-11900-001
July 18, 2013
Revision F
B.3 WX-1000/SKY497 DISPLAY ENVIRONMENTAL QUALIFICATION FORM
(Reference Document 016-10831-001, Rev. A)
NOMENCLATURE:
Stormscope
®
MODEL: WX-1000
TSO NO.: TSO-C113
PART NO.: 78-8060-5900-8
APPLICABLE SPEC. NO.: RTCA/DO-160C
MANUFACTURER: L-3 Communications Avionics Systems, Inc.
ADDRESS: 5353 52nd Street SE, Grand Rapids, MI 49512
(616) 949-6600
Revision & Change Number of DO-160: DO-160C
CONDITION
SECTION/
PARAGRAPH
TEST DESCRIPTION
Temperature and Altitude
4.0
Tested to Category F1-
Operating Low Temperature
4.5.1
-20
°
Celsius
Operating High Temperature
4.5.3
+55
°
Celsius
Short-Time Operating High Temp.
4.5.2
+70 Degrees Celsius
Loss of Cooling
4.5.4
-Not Applicable-
Ground Survival Low Temp.
4.5.1
-55 Degrees Celsius
Ground Survival High Temp.
4.5.2
+85 Degrees Celsius
Altitude
4.6.1
55,000 Feet MSL
Temperature Variation
5.0
Tested to Category C
Humidity
6.0
Tested to Category A
Operational Shock and Crash Safety
7.0
Operational Shock
7.2
6 g's Peak
Crash Safety
7.3
15 g's all axes
Vibration
8.0
Tested to Categories [NBM] Instrument Panel
Mount Without Vibration Isolators
Explosion Proofness
9.0
Category X - No test required
Waterproofness
10.0
Category X - No test required
Fluids Susceptibility
11.0
Category X - No test required
Sand and Dust
12.0
Category X - No test required
Fungus Resistance
13.0
Category X - No test required
Salt Spray
14.0
Category X - No test required
Magnetic Effect
15.0
Tested to Class Z
Power Input
16.0
Category X - No test required
Voltage Spike
17.0
Category X - No test required
Audio Frequency Susceptibility
18.0
Category X - No test required
Induced Signal Susceptibility
19.0
Tested to Category Z
Radio Frequency Susceptibility
20.0
Tested to Category U
The document reference is online, please check the correspondence between the online documentation and the printed version.