16
In-Fit Exercise Pools
IMPORTANT INFORMATION REGARDING ELECTRICAL INSTALLATION
NORTH AMERICA
Equipment Type
Electrical Rating
Branch Circuit
Circuit Break
1
2 pumps
240V 40A
3 wires + ground
50A
4 pumps
240V 48A
3 wires + ground
60A
5 pumps
240V 48A
3 wires + ground
60A
EXPORT
Equipment Type
Electrical Rating
Branch Circuit
Circuit Breaker
1
2 pumps
230V 32A
2 wires + ground
32/40A
4 pumps
230V 32A
2 wires + ground
32/40A
2 pumps
230V 32A
2 wires + ground
32/40A
4 pumps
230V 32A
2 wires + ground
32/40A
1. Circuit breaker amperages may vary according to the area of installation. Please check local
electrical codes to verify requirements and assure compliance. Spas purchased not fully
equipped may operate at a reduced total amp rating thus allowing installation of a lower rate
GFCI/RCD circuit breaker and service installation.
ELECTRICAL CONNECTIONS
To hook up your spa your authorized dealer or licensed electrician should follow
these instructions:
1. Remove the front cabinet panel.
2. Remove the cover for the equipment control pack.
3. Use ¾” flexible non-metallic conduit for a spa requiring 10 AWG or 8 AWG wire. Use 1”
flexible non-metallic conduit for a spa requiring 6 AWG wire. Run the conduit from the
power source to the spa, through the hole in the left or right front corner of the spa and
into the equipment control pack.
4. Pull the wires/cable through the conduit and through the cutout of the equipment
control pack. Secure the wires/cable with a 1” strain relief. Make sure only the uncut
sheathing is clamped at this opening.