37
In-Fit Exercise Pools
WATER SYSTEM
Symptom
Problem
Corrective Action
Pulsating jets
1. Water level low
2. Dirty filters
3. Filter intake / pump
intake restricted
4. Pump gate valve closed
5. Equipment malfunction
1. Fill with water to 5” (13cm)
below the top of spa
2. Clean filters
3. Remove obstruction
4. Open gate valve
5. Call for service
No jet action or action
is poor
1. Jets are turned off
2. Diverter valve turned
3. Water level low
4. Dirty filters
5. Pump gate valve closed
6. Air lock
1. Turn jets on by turning jet
face
2. Turn the diverter valve
clockwise or counterclock-
wise
3. Fill with water to 5” (13cm)
below the top of spa
4. Clean filters
5. Open gate valve
6. Prime pump (see page 26)
ELECTRICAL SYSTEM
Symptom
Problem
Corrective Action
Spa will not turn on in
any mode
1. No power
2. Equipment malfunction
1. Check circuit breaker and/
or GFCI
2. Call for service
Spa turns on by itself
1. Normal automatic daily
filtration cycle
2. Spa required heat to
maintain temperature
3. Freeze protection
engaged
4. Equipment malfunction
1. No action required
2. No action required
3. No action required
4. Call for service
Light is out
1. Automatic time out has
shut off light.
2. Burned out light bulb
1. Press
Light
key again to
start another cycle.
2. Replace light bulb
Pump shuts down unex-
pectedly while in use
1. Automatic timeout has
shut pump off
2. Motor overheated and
protective device has
shut down pump
1. Press
Jets
keys again to
start another cycle
2. Allow pump to cool. If
the pump does not
restart when
Jets
key is
pressed, call for service