e
5XT_UM_EN_1.0
w w w . l - a c o u s t i c s . c o m
13
Option C
ELECTRICAL HAZARD
Risk of electrical injuries.
Do not touch the screw terminals when they are connected to a powered amplified controler.
Turn off the amplified controller before any operation on the terminals.
Maximum of 16 enclosures per LA4
Four 5XT enclosures can be connected to each output channel on the LA4. Therefore, a single LA4 amplified
controller can drive up to 16 enclosures.
This option uses bare speaker wire and is therefore reserved to fixed installation.
Impedance load
16 Ω for 1 enclosure, 8 Ω for 2 enclosures and 4 Ω for 4 enclosures.
Connect the SpeakON
®
end of a
Custom SpeakON
®
to bare wire cable
to the OUT1-OUT3 connector of the
LA4.
Connect the
pos. (+) cable
to the IN+ screw terminal and the
neg. (-) cable
to the
IN-
screw terminal.
Apply the same cabling scheme with the OUT2-OUT4 connector of the LA4.
Use
speaker cable 2.5 mm²
to connect additional similar enclosures in parallel with the first ones.
LA4 option C