XTP_RM_ML_1
w w w . l - a c o u s t i c s . c o m
17 en
EN
3.
a.
Insert the enclosure’s top face pole socket into the U-bracket’s stud.
b.
Rotate the pivoting arm into position: the spring-loaded pin will re-engage automatically into its initial position.
c.
Select the desired enclosure’s orientation and firmly screw the knob.
Figure 15: Securing the ETR15P to the SB15P enclosure
Verify that the pivoting arm is secured by checking that the spring-loaded pin is engaged and
that the pivoting arm cannot move freely.
Verify that the enclosure is secured to the U-bracket by checking that it cannot rotate freely.
When installing the SB15P enclosure in the vertical orientation, always position the ETR15P U-
bracket with the fixed arm underneath the enclosure.
L-ACOUSTICS recommends using an additional safety point when rigging enclosures.
A safety eye-bolt accessory can be added using the 8mm/0.31in insert located on the rear face
of the SB15P enclosure (see Figure 18).
6.3.2
Disassembling
Disassembling should be carried out in the reverse order of assembly.