background image

Electro-acoustical description

Connectors

SpeakON connectors can be used interchangeably as IN or LINK connector.

A15 Focus
2 × 4-point speakON

A15 Wide
2 × 4-point speakON

Internal pinout for L-Acoustics 2-way passive enclosures

speakON points

1 +

1 -

2 +

2 -

Transducer conn

-

Not linked

Not linked

KS21
2 × 4-point speakON

Internal pinout for L-Acoustics subwoofers

speakON points

1 +

1 -

2 +

2 -

Transducer connectors LF +

LF -

Not linked

Not linked

A15 owner's manual (EN) version 1.2 

 19

Summary of Contents for A15 Focus

Page 1: ...A15 owner s manual EN ...

Page 2: ... manual EN version 1 2 Distribution date June 18 2019 2019 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher ...

Page 3: ... Preset description 18 Connectors 19 Rigging system description 20 A15 system rigging 20 Enclosures 22 A15 Wide Focus 22 KS21 23 Rigging elements for own arrays 24 A15 BUMP 24 M BAR 26 A15 RIGBAR 27 A15 LIFT 29 Rigging elements for stacked arrays 32 A TILT 32 KS21 OUTRIG 34 K2 JACK 35 Rigging elements for a single enclosure 37 A MOUNT 37 X BAR 38 Storage and handling elements 40 KS21 CHARIOT 40 KS...

Page 4: ...h A15 BUMP A15 RIGBAR 56 Flying a radial array with A15 LIFT 58 Flying a single enclosure with X BAR 64 Stacking 67 Stacking A15 Wide Focus on KS21 with A TILT 67 Stacking KS21 on KS21 CHARIOT 71 Attaching K2 JACK stabilizers to KS21 CHARIOT 73 Pole mounting 76 Connection to LA ampli ed controllers 78 Speci cations 79 APPENDIX A Authorized con gurations with A15 LIFT 94 APPENDIX B Installing the L...

Page 5: ... are familiar with the rigging techniques and safety recommendations outlined in this manual Ensure personnel health and safety During installation and set up personnel must wear protective headgear and footwear at all times Under no circumstances is personnel allowed to climb on a loudspeaker assembly Respect the Working Load Limit WLL of third party equipment L Acoustics is not responsible for a...

Page 6: ...sional applications As part of a continuous evolution of techniques and standards L Acoustics reserves the right to change the speci cations of its products and the content of its documents without prior notice Check www l acoustics com on a regular basis to download the latest document and software updates Read the maintenance section of this document before servicing the product Do not expose th...

Page 7: ... 70 110 or 90 asymmetrical and a range of accessories for vertical or horizontal deployment A15 deployment requires a single preset that is optimized to provide amazing plug and play performance for both A15 models regardless of L Fins con guration Performance can be further enhanced with L Acoustics software optimization tools A15 provides the low frequency contour of a large concert system and t...

Page 8: ...ion of techniques and standards L Acoustics reserves the right to change the speci cations of its products and the content of its document without prior notice Please check www l acoustics com on a regular basis to download the latest document and software updates Contact information For information on advanced corrective maintenance contact your Certi ed Provider or your L Acoustics representativ...

Page 9: ...O 7 0 7 m 2 3 ft DO10 10 m 32 8 ft and DO25 25 m 82 ft DOSUB LA8 breakout cable for four passive enclosures 4 mm gauge 8 point PA COM to 4 2 point speakON Information about the connection of the enclosures to the LA ampli ed controllers is given in this document Refer to the LA4X LA8 LA12X user manual for detailed instructions about the whole cabling scheme including modulation cables and network ...

Page 10: ...ision 3D acoustical and mechanical modeling software LA Network Manager Software for remote control and monitoring of ampli ed controllers Refer to the Soundvision help Refer to the LA Network Manager help Loudspeaker cables 0 7 m 5 m 10 m 25 m CH 1 CH 2 1 m SP 7 SP5 SP10 SP25 SP Y1 0 7 m 10 m 25 m SPK1 SPK2 SPK3 SPK4 5 m DO 7 DO10 DO25 DOSUB LA8 10 A15 owner s manual EN version 1 2 ...

Page 11: ... components Rigging elements A15 BUMP A15 LIFT A15 RIGBAR A TILT KS21 OUTRIG A MOUNT KS21 CHARIOT X BAR M BAR CLAMP250 LA SLING2T KS21 PLA KS21 COV KS21 CHARIOTCOV K2 JACK A15 owner s manual EN version 1 2 11 ...

Page 12: ...directivity to one of four settings 110 70 symmetric or 90 asymmetric 35 55 or 55 35 The same A15 preset drives all directivity settings of both enclosures Within a line source combine A15 Focus and A15 Wide with custom directivity settings to improve SPL mapping and throw capability 110 setting 55 55 12 A15 owner s manual EN version 1 2 ...

Page 13: ...Electro acoustical description 70 setting Set the ns in the 35 position to provide the system with a 2 dB on axis gain 2 kHz 35 35 90 settings 55 35 35 55 55 35 A15 owner s manual EN version 1 2 13 ...

Page 14: ... and a waveguide directivity pattern of 70 110 symmetric or 90 asymmetric 6 dB depending on the ns settings 1001 00010 000 Frequency Hz 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Angle Dispersion angle diagram of one upright A15 Focus using lines of equal sound pressure at 3 dB 6 dB 12 dB 14 A15 owner s manual EN version 1 2 ...

Page 15: ...iagram of one A15 Focus with 110 ns setting using lines of equal sound pressure at 3 dB 6 dB 12 dB 1001 00010 000 Frequency Hz 180 160 140 120 100 80 60 40 20 0 20 40 60 80 100 120 140 160 180 Angle Dispersion angle diagram of one A15 Focus with 70 ns setting using lines of equal sound pressure at 3 dB 6 dB 12 dB A15 owner s manual EN version 1 2 15 ...

Page 16: ...ency Hz 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Angle Dispersion angle diagram of one upright A15 Wide using lines of equal sound pressure at 3 dB 6 dB 12 dB 1001 00010 000 Frequency Hz 180 160 140 120 100 80 60 40 20 0 20 40 60 80 100 120 140 160 180 Angle Dispersion angle diagram of one A15 Wide with 110 ns setting using lines of equal sound pressure at 3 dB 6 dB 12 dB 16 A15 own...

Page 17: ...0 100 120 140 160 180 Angle Dispersion angle diagram of one A15 Wide with 70 ns setting using lines of equal sound pressure at 3 dB 6 dB 12 dB Symmetrical con gurations The A15 rigging system is designed to enable a completely symmetrical setup for stereo applications A15 owner s manual EN version 1 2 17 ...

Page 18: ...e OUT 1 PA IN A 0 dB 0 ms ON OUT 2 PA IN A 0 dB 0 ms ON OUT 3 PA IN B 0 dB 0 ms ON OUT 4 PA IN B 0 dB 0 ms ON KS21_60 outputs channels routing gain delay polarity mute OUT 1 SB IN A 0 dB 0 ms ON OUT 2 SB IN A 0 dB 0 ms ON OUT 3 SB IN A 0 dB 0 ms ON OUT 4 SB IN A 0 dB 0 ms ON KS21_60_C loudspeaker elements outputs channels routing gain delay polarity mute SR OUT 1 SR ON SB OUT 2 SB ON SB OUT 3 SB O...

Page 19: ...speakON A15 Wide 2 4 point speakON Internal pinout for L Acoustics 2 way passive enclosures speakON points 1 1 2 2 Transducer connectors Not linked Not linked KS21 2 4 point speakON Internal pinout for L Acoustics subwoofers speakON points 1 1 2 2 Transducer connectors LF LF Not linked Not linked A15 owner s manual EN version 1 2 19 ...

Page 20: ... feature the same rigging system consisting of two elements A rotating rigging arm A spring loaded pin Push and slide to unlock the spring loaded pin SHLAK The rigging elements are tted with yellow safety labels that are visible when they are not safely locked 20 A15 owner s manual EN version 1 2 ...

Page 21: ...plays two ground runners on the bottom and two matching tracks on the top Eight corner stops protect the side panels during handling The logo on the enclosure front can be rotated to adapt to every con guration A15 owner s manual EN version 1 2 21 ...

Page 22: ... LIFT p 29 A DIN580 compatible M8 threaded insert is available to implement a secondary safety Two sets of two lodgings and one insert provide further options for ying stacking or pole mounting a single enclosure or small arrays with X BAR p 38 A TILT p 32 or A MOUNT p 37 respectively 22 A15 owner s manual EN version 1 2 ...

Page 23: ...ription Two ergonomic handles are available for transportation KS21 KS21 features a 35 mm pole socket which contains an M20 150 insert to be compatible with standard and threaded poles A15 owner s manual EN version 1 2 23 ...

Page 24: ...gging frame for ying vertical arrays of A15 Wide Focus or KS21 A15 BUMP is equipped with rotating rigging arms and ball locking pins to match the rigging systems of A15 Wide Focus or KS21 on either side The rigging arms are tted with yellow safety labels that are visible when the rigging arm is not in use 24 A15 owner s manual EN version 1 2 ...

Page 25: ... 5 6 7 8 9 10 11 12 13 14 15 16 A15 BUMP can be used as the main lifting accessory for ying vertical arrays of A15 Wide Focus and KS21 with one or two lifting points A15 BUMP can be secured to the bottom of the array to implement pullback con gurations using the rear pickup point R Alternatively A15 RIGBAR p 27 can be used for pullback A laser mounting plate is available Refer to APPENDIX B Instal...

Page 26: ...d KS21 arrays It can be used as a front or rear extension M BAR is secured to the rigging frame with two T shaped ball locking pins ball locking pins storage position 17 pickup points are available They are compatible with Ø19 mm shackles WLL 3 25 t two provided 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 A15 owner s manual EN version 1 2 ...

Page 27: ... arrays of up to four A15 Wide Focus or KS21 A15 RIGBAR is equipped with rotating rigging arms and ball locking pins to match the rigging systems of A15 Wide Focus or KS21 on either side The rigging arms are tted with yellow safety labels that are visible when the rigging arm is not in use A15 owner s manual EN version 1 2 27 ...

Page 28: ...sed as a pullback either with A15 BUMP or another A15 RIGBAR as the main lifting accessory A15 RIGBAR can be used as the main lifting accessory to provide a lightweight solution for ying four A15 Wide Focus or KS21 with one or two lifting points 28 A15 owner s manual EN version 1 2 ...

Page 29: ...s implement a secondary safety using available holes One pickup point safety points pickup point Two pickup points pickup points safety point A15 LIFT A15 LIFT is a rigging element designed to y a radial array of up to three A15 Wide Focus A15 LIFT features two studs that match the lodgings at the front and rear of the enclosure studs A15 owner s manual EN version 1 2 29 ...

Page 30: ...able radial array of A15 Wide Focus can be created using multiple A15 LIFT A15 LIFT quantity and position Use one A15 LIFT for up to three enclosures in the array Do not leave more than two adjacent enclosures unsupported Refer to APPENDIX A Authorized con gurations with A15 LIFT p 94 Risk of tilting When using a single motor or a bridle make sure the array is symmetrical When using a third party ...

Page 31: ...same pickup point on each A15 LIFT within an array of up to 6 enclosures For larger arrays refer to Radial arrays of 7 enclosures and more p 95 Hole 11 serves as a setup point in the radial array procedure see Flying a radial array with A15 LIFT p 58 It is identi ed by a mark on the label 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 setup point FRONT A15 owner s manual EN version 1 2 31 ...

Page 32: ...r to Attaching K2 JACK stabilizers to KS21 CHARIOT p 73 Do not use A TILT in a own array The studs on A TILT match the lodgings on the enclosure to enable deployments with the HF section on either side A TILT is secured to the enclosure and to the subwoofer with threaded knobs A TILT compatible subwoofers The A TILT subwoofer knob can only be secured in pole mount sockets that contain an M20 inser...

Page 33: ...bel displays the opening angle of the accessory and not the site angle of the enclosure Refer to Stacking A15 Wide Focus on KS21 with A TILT p 67 for the list of realized site angles Four 11 mm holes are available to secure the assembly to the oor 11 mm hole x4 A15 owner s manual EN version 1 2 33 ...

Page 34: ... Secure KS21 OUTRIG at the bottom of a KS21 array to improve the stability of the array The use of KS21 OUTRIG is mandatory when A15 Wide FocusA15 Wide Focus or A10 Wide Focus are stacked on top of KS21 KS21 OUTRIG matches the rigging system of KS21 SHLAK 34 A15 owner s manual EN version 1 2 ...

Page 35: ...K2 JACK K2 JACK is a set of a two bars and four feet with screw jacks and hand wheels K2 JACK can be tted onto KS21 CHARIOT p 40 to improve stability or correct oor discrepancies During transportation make sure the bolts are tightened bolts x4 feet with screw jacks locking handles hand wheels storage position position in use A15 owner s manual EN version 1 2 35 ...

Page 36: ...Rigging system description 36 A15 owner s manual EN version 1 2 ...

Page 37: ...gings on the enclosure A MOUNT features two axis the front one can be moved to change the site angle studs angle axis enclosure knob in use wedge clamp position in use The enclosure knob can be stored in an insert on the side The angle axis is secured with a threaded knob To optimize visual impact the knob can be replaced by a locking cotter pin provided enclosure knob stored enclosure knob stored...

Page 38: ...ide Focus p 76 for the list of realized site angles X BAR X BAR is a rigging bar for ying A15 Wide Focus The rigging system consists of a threaded axis with a cam lever X BAR is secured to the dedicated inserts on the enclosure in front or rear extension position 38 A15 owner s manual EN version 1 2 ...

Page 39: ...Rigging system description Five angulation holes are available 5 4 3 2 1 X BAR is compatible with a Ø12 mm shackle WLL 1 t provided and with CLAMP250 A15 owner s manual EN version 1 2 39 ...

Page 40: ...ures two rigging arms to secure the lower KS21 Risk of damage Do not secure A15 Wide Focus directly on KS21 CHARIOT Do not move or transport more than three enclosures on KS21 CHARIOT 1904 mm 75 in KS21 CHARIOT features two brakes for optimal stability Risk of brake damage Do not use the brakes during transportation 40 A15 owner s manual EN version 1 2 ...

Page 41: ... be stacked for storage KS21 PLA KS21 PLA is a dolly board that can be secured to the front of a KS21 with two spring loaded pins Multiple KS21 PLA can be stacked for storage Turn the wheels outwards to stack KS21 PLA A15 owner s manual EN version 1 2 41 ...

Page 42: ... plate KS21 CHARIOTCOV is a cover for a stack of two to three KS21 on KS21 CHARIOT To t a stack of two KS21 KS21 CHARIOTCOV must be folded inwards and secured with the integrated velcro straps foldable flaps to access the connectors the logo must be on the front face velcro straps inside KS21 COV KS21 CHARIOTCOV 42 A15 owner s manual EN version 1 2 ...

Page 43: ...rective when the other deployment parameters provide the best mechanical conditions For mixed arrays refer to your Soundvision model KS21 con guration rigging accessory safe limit maximum limit Vertical array A15 BUMP 8 16 Vertical array A15 RIGBAR 4 A15 Wide Focus con guration rigging accessory maximum safe limit Flown X BAR 1 Vertical array A15 BUMP M BAR optional 8 Vertical array A15 RIGBAR 4 1...

Page 44: ...y factor will depend on numerous variables linked to the composition of the array type and number of enclosures splay angles and the implementation of the ying or stacking structure number and location of ying points site angle This cannot be determined without the complex mechanical modeling and calculation offered by Soundvision Assessing the safety with Soundvision The overall safety factor of ...

Page 45: ...r the nominal bandwidth of the enclosures The A15 preset delivers a reference frequency response in medium throw applications The A15 Wide Focus enclosures are driven by the LA4X LA8 LA12X ampli ed controllers Preset A15 Frequency range 10 dB 41 Hz 20 kHz A15 Focus 42 Hz 20 kHz A15 Wide A15 owner s manual EN version 1 2 45 ...

Page 46: ...d ratio 1 A15 Wide Focus 1 KS21 Frequency range 10 dB 29 Hz 20 kHz Use xxxx_xx_C on a reversed subwoofer in a cardioid con guration The cardioid con guration consists in reversing 1 element in an array of 4 subwoofers Grouping subwoofers Place the subwoofer enclosures side by side If not possible the maximum distance between two adjacent acoustic centers must be 2 8 m or 1 7 m if the upper frequen...

Page 47: ... system operates over the nominal bandwidth of the enclosure The A15_FI preset delivers a reference frequency response in short throw applications The A15 Wide Focus enclosure are driven by the LA4X LA8 LA12X ampli ed controllers Preset A15_FI Frequency range 10 dB 42 Hz 20 kHz A15 Focus 43 Hz 20 kHz A15 Wide A15 owner s manual EN version 1 2 47 ...

Page 48: ... kHz Use xxxx_xx_C on a reversed subwoofer in a cardioid con guration The cardioid con guration consists in reversing 1 element in an array of 4 subwoofers Refer to the subwoofer owner s manual and to the Cardioid con gurations technical bulletin Grouping subwoofers Place the subwoofer enclosures side by side If not possible the maximum distance between two adjacent acoustic centers must be 2 8 m ...

Page 49: ...at no unattached items remain on the product or assembly Secondary safety Use available holes on the rigging accessories to implement a secondary safety Array orientation Under A15 BUMP and A15 RIGBAR the enclosure HF section can be oriented both ways Under KS21 the HF section is on the same side as the subwoofer vent A15 Wide Focus array Procedure 1 Stack up to three enclosures Connect each enclo...

Page 50: ...AR Connect A15 BUMP to the top enclosure on both sides CLICK Connect A15 RIGBAR to the top enclosure on both sides CLICK Final check Visually check that no yellow labels are visible Manually check that all linking points are secured 3 Select the pick up point and raise the array 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 F R FRONT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 50 A15 owner s manual EN version...

Page 51: ...gging system is locked 4 One by one secure additional enclosures under the array Connect each enclosure on both sides before adding the next one SHLAK Final check Visually check that no yellow labels are visible Manually check that all linking points are secured A15 owner s manual EN version 1 2 51 ...

Page 52: ...dvision for maximum con gurations Procedure 1 Prepare a stack of KS21 Connect each enclosure on both sides before adding the new one SHLAK 2 Secure A15 BUMP or A15 RIGBAR on top of the array A15 BUMP A15 RIGBAR Connect A15 BUMP to the top KS21 on both sides Connect A15 RIGBAR to the top KS21 on both sides CLICK CLICK 52 A15 owner s manual EN version 1 2 ...

Page 53: ...d additional enclosures under the array KS21 A15 Focus or A15 Wide Lower the array onto a KS21 or a stack of KS21 on KS21 CHARIOT Align the runners and the tracks Unlock the KS21 CHARIOT rigging arms This step requires two operators Hold the enclosure by the handle until the rigging system is locked One by one lift the enclosures and secure them under the array 5 Connect the enclosure on both side...

Page 54: ...eck Visually check that no yellow labels are visible Manually check that all linking points are secured Disassembly Removing a stack of KS21 Procedure 1 Position a KS21 CHARIOT under the array 54 A15 owner s manual EN version 1 2 ...

Page 55: ...eed slowly when lowering the array 2 Lower the array until it rests on KS21 CHARIOT 3 Secure the bottom enclosure to KS21 CHARIOT SHLAK 4 Disconnect a stack from the array on both sides Make sure both linking points are disconnected before lifting the array 5 Lift the assembly and put the stack aside 6 Repeat the procedure A15 owner s manual EN version 1 2 55 ...

Page 56: ...tached items remain on the product or assembly Assembly Procedure 1 Prepare a vertical array as described in Flying a vertical array with A15 BUMP A15 RIGBAR p 49 2 Raise the array until the bottom enclosure is accessible 3 Secure A15 BUMP or A15 RIGBAR under the array A15 BUMP A15 RIGBAR Connect A15 BUMP to the bottom enclosure on both sides Connect A15 RIGBAR to the bottom enclosure on both side...

Page 57: ...ually check that no yellow labels are visible Manually check that all linking points are secured 4 Secure a shackle to A15 RIGBAR or to pickup point R on A15 BUMP and lift it with an additional motor A15 owner s manual EN version 1 2 57 ...

Page 58: ...enclosure on which A15 LIFT is secured secure a DIN580 eye bolt to the dedicated insert to implement a secondary safety Use a shackle and a steel wire rope Make sure the steel rope is as tensed as possible without bearing the load A15 LIFT quantity and position Use one A15 LIFT for up to three enclosures in the array Do not leave more than two adjacent enclosures unsupported Refer to APPENDIX A Au...

Page 59: ...locks of up to three enclosures Refer to Preparing a block of enclosures p 62 2 Connect the enclosures at the top Pull the enclosures together to align the rigging SHLAK Final check Visually check that no yellow labels are visible Manually check that all linking points are secured A15 owner s manual EN version 1 2 59 ...

Page 60: ...5 LIFT bars on the array a Disconnect the ball locking pin at the rear of A15 LIFT b Insert the stub at the front of the enclosure c Insert the stub at the rear and secure the ball locking pin CLICK 60 A15 owner s manual EN version 1 2 ...

Page 61: ...he bottom rigging is accessible For this operation stand behind the array 6 Connect the enclosures at the bottom Pull the enclosures together to align the rigging SHLAK 7 Lower the array to select the desired pickup points A15 LIFT pickup point Select the same pickup point on each A15 LIFT within an array of up to 6 enclosures For larger arrays refer to Radial arrays of 7 enclosures and more p 95 ...

Page 62: ...parate the array into blocks of two or three enclosures Connect each enclosure on both sides before adding the new one SHLAK This step requires two operators Make sure all unused rigging arms are in storage position 2 Position the enclosure blocks upright logo on top in two steps Tilt the enclosures on the rear Tilt the enclosures upright 3 Proceed as described in Assembly p 59 62 A15 owner s manu...

Page 63: ...5 6 7 8 9 10 11 12 13 14 15 16 17 setup point FRONT Make sure the pickup points are on hole 11 before lifting the array 3 Raise the array until the bottom rigging is accessible 4 Disconnect the enclosures at the bottom SHLAK Make sure all unused rigging arms are in storage position 5 Lower the array to the ground A15 owner s manual EN version 1 2 63 ...

Page 64: ...rrays When ying an enclosure or an array use the M8 DIN580 threaded insert to implement a secondary safety Realized site angles A15 Focus A15 Wide X BAR hole N o rear extension front extension rear extension front extension 1 8 4 10 6 9 13 6 2 0 5 1 2 8 3 4 3 9 4 7 8 13 2 6 5 4 18 5 16 2 23 7 15 7 5 27 5 24 8 34 6 25 1 Assembly Procedure 1 Drive the X BAR in the insert 64 A15 owner s manual EN ver...

Page 65: ...icular to the front grill Use the lodgings as reference points 3 Tighten the X BAR a Lift the lever and rotate it counter clockwise release the lever and rotate it clockwise Repeat until the X BAR is tightly secured A15 owner s manual EN version 1 2 65 ...

Page 66: ...Rigging procedures b Finally store the lever on the right 4 Select the site angle and secure a shackle or CLAMP250 5 4 3 2 1 66 A15 owner s manual EN version 1 2 ...

Page 67: ...e A TILT in a own array Alternatively mount the KS21 array on KS21 CHARIOT and use K2 JACK to stabilize the array Refer to Attaching K2 JACK stabilizers to KS21 CHARIOT p 73 Realized site angles realized site angle selected angle on A TILT A15 Focus A15 Wide 12 5 7 5 2 5 15 10 0 17 5 12 5 2 5 20 15 5 22 5 17 5 7 5 25 20 10 Assembly Procedure 1 Secure KS21 OUTRIG under a KS21 Turn the KS21 upside d...

Page 68: ...t each enclosure on both sides before adding the new one SHLAK 3 Select the widest opening position on A TILT 25 4 Place A TILT on A15 Wide Focus using the lodgings for indexation Consider the nal position of the enclosure 68 A15 owner s manual EN version 1 2 ...

Page 69: ...s 5 Secure A TILT to the enclosure with the enclosure knob 6 Place the assembly on KS21 7 Adjust the position of A TILT and secure the subwoofer knob inside the pole mounting socket A15 owner s manual EN version 1 2 69 ...

Page 70: ... downwards 8 Adjust the site angle Insert the angle pins in the selected opening angle on both sides 20 9 Optionally secure additional enclosures on top of the assembly SHLAK Final check Visually check that no yellow labels are visible Manually check that all linking points are secured 70 A15 owner s manual EN version 1 2 ...

Page 71: ... KS21 CHARIOT Min number of operators 2 Risk of falling objects Verify that no unattached items remain on the product or assembly Assembly Procedure 1 Engage both brakes on KS21 CHARIOT 2 Place KS21 on KS21 CHARIOT and connect the two elements on both sides SHLAK A15 owner s manual EN version 1 2 71 ...

Page 72: ...SHLAK 4 Repeat until the stack is complete Final check Visually check that no yellow labels are visible Manually check that all linking points are secured 5 Disengage the brakes and position the stack at its nal position 6 Block the stack using both brakes 72 A15 owner s manual EN version 1 2 ...

Page 73: ...cked array Rigging accessory K2 JACK KS21 CHARIOT Min number of operators 1 Assembly Procedure 1 Attach the K2 JACK bars to KS21 CHARIOT on each side a Open the locking handles to insert the studs b Raise and turn the locking handles to secure the bars A15 owner s manual EN version 1 2 73 ...

Page 74: ...l the central part is close to the base 3 Attach the feet to the bar Insert the feet at both ends of the bar Pivot the central part so that it comes in contact with the bar Lock the feet in position by giving a quarter turn to the locking system 74 A15 owner s manual EN version 1 2 ...

Page 75: ...Rigging procedures Stop raising the stack as soon as the wheels get off the ground 4 Rotate the wheels clockwise to raise the array A15 owner s manual EN version 1 2 75 ...

Page 76: ... site angles realized site angle selected angle on A MOUNT A15 Wide A15 Focus 15 0 10 5 10 0 0 15 5 Assembly Procedure 1 Place A MOUNT on the enclosure using the lodgings for indexation Consider the nal position of the enclosure FRONT 2 Remove the angle axis and secure A MOUNT to the enclosure with the threaded knob 76 A15 owner s manual EN version 1 2 ...

Page 77: ...Rigging procedures 3 Select the site angle and insert the axis in the corresponding hole 5 4 Mount the assembly on a pole and tighten the wedge clamp by hand A15 owner s manual EN version 1 2 77 ...

Page 78: ...s 1 4 2 8 3 12 KS21 1 4 2 6 2 8 Cabling schemes for A15 Wide Focus KS21 Refer to the cabling schemes to connect the enclosures to different types of output connectors One channel speakON output SP SP 1 1 Two channel speakON output SP SP SP Y1 CC4FP CH 1 CH 2 1 1 2 2 Four channel CA COM output DO SP DOSUB LA8 SPK1 SPK2 SPK3 SPK4 For passive loudspeakers the value corresponds to the number of enclos...

Page 79: ...HF DOSC waveguide L Fins Nominal impedance 8 Ω Connectors IN 1 4 point speakON LINK 1 4 point speakON Rigging and handling ush tting two point rigging system 2 handles 8 corner stops 2 ground runners 1 DIN580 compatible M8 threaded insert Weight net 35 kg 77 lb Cabinet premium grade Baltic beech and birch plywood Front steel grill with coating acoustically neutral 3D fabric Rigging components high...

Page 80: ...Speci cations A15 Focus dimensions 427 mm 16 8 in 762 mm 30 in 431 mm 17 in 347 mm 13 7 in 490 mm 19 3 in 752 mm 29 6 in 522 mm 20 6 in 80 A15 owner s manual EN version 1 2 ...

Page 81: ... waveguide L Fins Nominal impedance 8 Ω Connectors IN 1 4 point speakON LINK 1 4 point speakON Rigging and handling ush tting two point rigging system 2 handles 8 corner stops 2 ground runners 1 DIN580 compatible M8 threaded insert Weight net 33 kg 73 lb Cabinet premium grade Baltic beech and birch plywood Front steel grill with coating acoustically neutral 3D fabric Rigging components high grade ...

Page 82: ...Speci cations A15 Wide dimensions 424 mm 16 7 in 762 mm 30 in 182 mm 7 2 in 494 mm 19 4 in 752 mm 29 6 in 525 mm 20 7 in 82 A15 owner s manual EN version 1 2 ...

Page 83: ... speakON LINK 1 4 point speakON Rigging and handling ush tting two point rigging system 4 handles 8 corner stops 2 ground runners 1 pole mount with M20 150 insert Weight net 49 kg 108 lb Cabinet premium grade Baltic beech and birch plywood Front steel grill with coating acoustically neutral 3D fabric Rigging components high grade steel with anti corrosion coating Finish dark grey brown Pantone 426...

Page 84: ...Speci cations KS21 dimensions 571 mm 22 5 in 762 mm 30 in 576 mm 22 7 in 569 mm 22 4 in 602 mm 23 7 in 752 mm 29 6 in 620 mm 24 4 in 575 mm 22 6 in 84 A15 owner s manual EN version 1 2 ...

Page 85: ...ame for vertical deployment of A15 and KS21 2 Ø12 mm shackles WLL 1 t Weight net 19 kg 42 lb Material high grade steel with anti corrosion coating A15 BUMP dimensions 77 mm 3 in 656 mm 25 8 in 600 mm 23 6 in 754 mm 29 7 in A15 owner s manual EN version 1 2 85 ...

Page 86: ...sion coating A15 LIFT dimensions 139 mm 5 5 in 50 mm 2 in 25 mm 1 in 629 mm 24 8 in A15 RIGBAR speci cations Description Rigging bar and pullback for A15 and KS21 2 Ø12 mm shackles WLL 1 t Weight net 4 6 kg 10 lb Material high grade steel with anti corrosion coating A15 RIGBAR dimensions 750 mm 29 5 in 64 mm 2 5 in 18 mm 0 7 in 89 mm 3 5 in 10 mm 0 4 in 86 A15 owner s manual EN version 1 2 ...

Page 87: ...0 mm 14 2 in 415 mm 16 3 in 127 mm 5 in KS21 OUTRIG speci cations Speci cations for one KS21 OUTRIG bar Always use in pairs Description Stability bars for KS21 Weight net 3 5 kg 7 7 lb Rigging and handling 2 ground runners Material high grade steel with anti corrosion coating high density polyethylene runners KS21 OUTRIG dimensions 900 mm 35 4 in 55 mm 2 2 in 68 3 mm 2 7 in A15 owner s manual EN v...

Page 88: ...le mount for A15 and A10 Weight net 1 1 kg 2 4 lb Material high grade steel with anti corrosion coating A MOUNT dimensions Ø 36 mm 1 4 in 152 mm 6 in 68 mm 2 7 in 152 mm 6 in 97 mm 3 8 in 131 mm 5 1 in 115 mm 4 5 in 88 A15 owner s manual EN version 1 2 ...

Page 89: ... cations KS21 CHARIOT speci cations Description Chariot for 3 KS21 Weight net 23 6 kg 52 lb KS21 CHARIOT dimensions 712 mm 28 in 840 mm 33 in 67 8 mm 2 6 in 225 mm 8 9 in A15 owner s manual EN version 1 2 89 ...

Page 90: ... steel with anti corrosion coating K2 JACK dimensions 426 mm 16 8 in 1278 mm 50 3 in 124 mm 4 9 in M BAR speci cations Description Extension bar for rigging frame 2 Ø19 mm shackles WLL 3 25 t Weight net 5 kg 11 lb Material high grade steel with anti corrosion coating M BAR dimensions 60 mm 2 4 in 954 mm 37 6 in 112 mm 4 4 in 90 A15 owner s manual EN version 1 2 ...

Page 91: ...ion Rigging bar for 1 enclosure 1 Ø12 mm shackle WLL 1 t Weight net 1 1 kg 2 4 lb Material high grade steel with anti corrosion coating X BAR dimensions 185 mm 7 3 in Ø 13 mm 0 5 in 83 mm 3 3 in 85 mm 3 3 in A15 owner s manual EN version 1 2 91 ...

Page 92: ...peci cations Description Clamp certi ed for 250 kg Weight net 1 8 kg 4 lb Material high grade steel with anti corrosion coating CLAMP250 dimensions 167 mm 6 6 in 103 mm 4 1 in 227 mm 8 9 in 92 A15 owner s manual EN version 1 2 ...

Page 93: ...ations KS21 PLA speci cations Description Removable front dolly for 1KS21 Weight net 9 5 kg 21 lb KS21 PLA dimensions 148 mm 5 8 in 20 mm 0 8 in 569 mm 22 4 in 738 mm 29 in A15 owner s manual EN version 1 2 93 ...

Page 94: ...ne A15 LIFT for up to three enclosures in the array Do not leave more than two adjacent enclosures unsupported A15 LIFT pickup point Select the same pickup point on each A15 LIFT within an array of up to 6 enclosures For larger arrays refer to Radial arrays of 7 enclosures and more p 95 Risk of tilting When using a single motor or a bridle make sure the array is symmetrical When using a third part...

Page 95: ...e array In radial arrays of 7 enclosures and more make sure the site angle is 0 Position the pickup points to that the center of gravity is in the middle of the array Setup point for radial arrays of 7 enclosures and more For each con guration use the indicated setup point during assembly 7 enclosures 3 A15 LIFT 8 enclosures 4 A15 LIFT 9 enclosures 3 A15 LIFT Array setup information type number of...

Page 96: ...e with the new TEQSAS LAP TEQ PLUS displays Conversely the new sensors are not compatible with the legacy displays With two sets of xation points and eight slit openings the position and orientation of the laser support plate can be adapted to every use of the rigging frame support plate slit openings front slit openings rear fixation points front fixation points rear Calibrating the inclinometer ...

Page 97: ... recommended maximum length for loudspeaker cables depending on the cable gauge and on the impedance load connected to the ampli er recommended maximum length cable gauge 8 Ω load 4 Ω load 2 7 Ω load mm 2 SWG AWG m ft m ft m ft 2 5 15 13 30 100 15 50 10 33 4 13 11 50 160 25 80 17 53 6 11 9 74 240 37 120 25 80 For installation projects use the more detailed L Acoustics calculation tool to evaluate ...

Page 98: ...ww l acoustics com L Acoustics GmbH Steiermärker Str 3 5 70469 Stuttgart Germany 49 7 11 89660 323 L Acoustics Ltd PO Box Adler Shine Aston House Cornwall Avenue London N3 1LF United Kingdom 44 7224 11 234 L Acoustics Inc 2645 Townsgate Road Suite 600 Westlake Village CA 91361 USA 1 805 604 0577 L GROUP www l group com ...

Reviews: