Loudspeaker connection
Connection to LA12X
Maximum number of enclosures per LA12X
enclosure
max enclosures in parallel
*
max enclosures per controller
K1
2
2
K2
3
3
Kara
3
6
K1-SB
1
4
KS28
1
4
SB28
1
4
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
Risks of output mute, global attenuation, or loss of audio quality.
Do not exceed the maximum number of connected enclosures per channel and in total.
Driving more enclosures than indicated can trigger the amplied controller protection systems.
Impedance load
K1
1 enclosure: LF 8 Ω / MF 8 Ω / HF 8 Ω
2 enclosures in parallel: LF 4 Ω / MF 4 Ω / HF 4 Ω
K2
1 enclosure: LF 8 Ω / MF 8 Ω / HF 16 Ω
2 enclosures in parallel: LF 4 Ω / MF 4 Ω / HF 8 Ω
3 enclosures in parallel: LF 2.7 Ω / MF 2.7 Ω / HF 5.2 Ω
Kara
1 enclosure: LF 8 Ω / HF 8 Ω
2 enclosures in parallel: LF 4 Ω / HF 4 Ω
3 enclosures in parallel: LF 2.7 Ω / HF 2.7 Ω
SB28 KS28 K1-SB
1 enclosure: 4 Ω
Connecting 3-way active enclosures
DO on CA-COM output
CA-COM
DO
DO
20
K1 user manual (EN) version 6.0
Summary of Contents for K1