K2 WST
®
enclosure
RIGGING MANUAL
VERSION 3.0
K2_RM_EN_3.0
w w w . l - a c o u s t i c s . c o m
8 / 76
2
MECHANICAL SAFETY
2.1
Mechanical limits
The K2 rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines of
BGV-C1.
2006/42/EC: Machinery Directive specifies a safety factor of 4:1 against the rupture. The limits specified in the tables
below correspond to a safety factor of 4:1 or higher for flown deployments. Refer to SOUNDVISION for the safety
factor of a specific deployment.
The
safe limit
gives the maximum number of elements for which the safety factor is always compliant with the
2006/42/EC: Machinery Directive, regardless of the other deployment parameters (site angles, inter-enclosure angles,
etc.).
The
maximum limit
gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
Ground-stacked
Safe limit
Maximum limit
K2-BUMP
or
K2-CHARIOT with K2-JACK
4 K2
6 K2
Flown
Safe limit
Maximum limit
K2-BUMP
K2-BUMP + K2-BAR
16 K2
14 K2 + 2 LA-RAK
12 K1-SB + 1 LA-RAK
24 K2
24 K2 + 2 LA-RAK
16 K1-SB + 2 LA-RAK
K2-LINK under K1-BUMP
16 K2
24 K2
K2-RIGBAR
12 K2
SOUNDVISION and mechanical safety
To deploy more elements than the safe limits, or when mixing different type of loudspeaker enclosures
within the same array, always model the system in SOUNDVISION before installation, and check the
Mechanical Data section for any stress warning or stability warning.