Loudspeaker connection
Connection to LA4X
Maximum number of enclosures per LA4X
enclosure
max enclosures in parallel
*
max enclosures per controller
K2
1
1
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
Impedance load
K2
1 enclosure: LF 8 Ω / MF 8 Ω / HF 16 Ω
Connecting 3-way active enclosures
custom speakON-to-PA-COM on speakON output
L-Acoustics does not supply the speakON-to-PA-COM interface.
It must be built with two 4-point speakON connectors and a female 8-point PA-COM connector (no cable clamp).
OUT1/OUT2
OUT3/OUT4
speakON to PA-COM
Connection to LA12X
Maximum number of enclosures per LA12X
enclosure
max enclosures in parallel
*
max enclosures per controller
K2
3
3
K1-SB
1
4
KS28
1
4
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
Impedance load
K2
1 enclosure: LF 8 Ω / MF 8 Ω / HF 16 Ω
2 enclosures in parallel: LF 4 Ω / MF 4 Ω / HF 8 Ω
3 enclosures in parallel: LF 2.7 Ω / MF 2.7 Ω / HF 5.2 Ω
KS28 K1-SB
1 enclosure: 4 Ω
19
K2/KS28 user manual (EN) version 3.0
Summary of Contents for K2
Page 1: ...K2 KS28 user manual EN...